66(83)
4. Operation
4.1 Control Panel
Picture 4-1
:
Control Panel
Table 4-1
:
Control Panel Table
No.
Name
Function description
Remarks
1
Running indicating
Indicates the working status of
blower and heater
Green light on indicates working
status
Green light off indicates stop
status
2
Fault indicating
Indicates current alarm message
Red light on indicates fault occurs
3
Time start
Set weekly start or intermittent
start/stop
When time has been set, press
this key to set time start mode
4
Temp/time shift key
Display alternatively in between
temp. And time for temp or time
set up
5
Start/stop key
Control the start and stop of the
machine
Press to start at stop status.
Press to stop at working status.
6
Real value indicated
by LED
Display real drying temperature
or parameter code
7
Set value indicated
by LED
Display the set drying
temperature
8
Increase set value
Increase set value
9
Set key
Enter or exit value setting
10
Confirm key
Confirm the input of data
11
Decrease set value
Decrease the set value
12
Buzzer
Buzzer keeps on when fault
exists
Buzzer only silence after trouble
shooting
13
Dew-point
Dew-point display
Display real timely the moisture content
within the material