47(83)
2) Drying process menu.
Drying process menu is as shown below:
Picture 2-19
:
Drying Process Screen
A. Operation of the menu
Start the system:
Touch the start switch to make it show ON, then the system starts.
Stop the system:
Touch the start switch again to make it show OFF, then the system stops
running.
(Attention: In order to prolong the life of honeycomb-rotor, it
’
s necessary to
delay the stop time of the rotor for cooling. Set the delayed time at about 2~3
minutes. Please see more details of setting on the time parameter setting
screen.)
Setting of regeneration temp.; Touch the preset value of regeneration temp. A
keypad will appear. Use the keypad to input temperature values.
Note!
Regeneration temp. value is set between a certain limits. The systen has
set its regeneration temp in the ranges of 130--180
and 00
℃
--130
! The
℃
Factuary Default is130
or 180
. Do not
℃
℃
reset except in special
circumstances.