background image

 

OFS-80

 

Optical Fiber Fusion Splicer User’s Manual 

 

Shineway Technologies, Inc.                  

 

- viii -

 

 

Possible equipment failure may result. 

 

 

Do  not  touch  protection  sleeve  or  tube-heater  during  heating  or  immediately  after 

completion of heating. Their surfaces are very hot and touching these may result in skin 

burn. 

 

 

Do not place the splicer in an unstable or unbalanced position. The splicer may shift or 

lose  balance,  causing  the  unit  to  fall.  Possible  personal  injury  or  equipment  damage 

may result. 

 

 

The splicer is precision adjusted and aligned. Do not allow the unit to receive a strong 

shock or impact. Possible equipment failure may result. Use supplied carrying case for 

transportation  and  storage.  The  carrying  case  protects  the  splicer  from  damage, 

moisture, vibration and shock during storage and transportation. 

 

 

Follow the below listed instructions for handling electrodes. 

 

Use only specified electrodes. 

 

Set the new electrodes in the correct position. 

 

Replace the electrodes as a pair. 

Failure to follow the above instructions may cause abnormal arc discharge. It can result 

in equipment damage or degradation in splicing performance. 

 

 

Do not use any chemical other than pure alcohol (99% or greater) to clean the objective 

lens,  V-groove,  mirror,  LCD  monitor,  etc.,  of  the  splicer.  Otherwise  blurring, 

discoloration, damage or deterioration may result.     

 

 

The splicer requires no lubrication. Oil or grease may degrade the splicing performance 

and damage the splicer. 

 

 

The  equipment  must  be  repaired  or  adjusted  by  a  qualified  technician  or  engineer. 

Incorrect  repair  may  cause  fire  or  electric  shock.  Should  any  problems  arise,  please 

contact your nearest sales agency. 

Summary of Contents for OFS-80

Page 1: ...OFS 80 Optical Fiber Fusion Splicer User s Manual Shineway Technologies Inc...

Page 2: ...OFS 80 Optical Fiber Fusion Splicer...

Page 3: ...but not limited to the implied warranties of merchantability and fitness for a particular purpose Shineway Technologies Inc shall not be liable for errors contained herein or for incidental or conseq...

Page 4: ...meters For more details please refer to the specifications tables Before Applying Power Verify that the product is set to match the available line voltage the correct fuse is installed and all safety...

Page 5: ...instructions Stop using it when it malfunctions and ask our service centers for repair as soon as possible Read this instruction manual carefully before operating this machine Disconnect the AC power...

Page 6: ...eplacing electrodes Safety glasses should always be worn during fiber preparation and splicing operation Fiber fragments can be extremely dangerous if it comes into contact with the eye skin or is ing...

Page 7: ...d and AC plugs with wet hands This may result in electric shock Do not operate splicer near hot objects in hot temperature environments in dusty humid atmospheres or when water condensation is present...

Page 8: ...icer from damage moisture vibration and shock during storage and transportation Follow the below listed instructions for handling electrodes Use only specified electrodes Set the new electrodes in the...

Page 9: ...1 2 Turning Splicer ON 15 3 1 3 LCD Brightness Adjustment 15 3 2 Fiber Preparation 16 3 2 1 Placing Protection Sleeve over Fiber 16 3 2 2 Stripping and Cleaning Fiber 16 3 2 3 Fiber Cleaving 17 3 2 4...

Page 10: ...OFS 80 Optical Fiber Fusion Splicer User s Manual Shineway Technologies Inc x 6 3 Warranty Registration 29 6 4 Returning Instruments 29 6 5 Contacting Customer Service 30...

Page 11: ...c immediately Retain the original packing materials in case reshipment becomes necessary 1 2 Unpacking and Inspection This instrument has been carefully packed in accordance with standard shipping pro...

Page 12: ...n size and light in weight making it suitable for any operating environment It is easy to operate and it splices fast while maintaining low splice loss In order to achieve the splicer s full capabilit...

Page 13: ...OFS 80 Optical Fiber Fusion Splicer User s Manual Shineway Technologies Inc 13 V groove Guide Groove Electrode Cover Wind Protector Mirror Fiber Clamp Sheath Clamp Electrode Cover Sheath Clamp...

Page 14: ...ace Detaching power supply unit Turn off the splicer Push the release button located on the side of the splicer body and remove the power supply out of the splice body Two ways to check remaining batt...

Page 15: ...played after all the motors reset to their initial positions The power source type is automatically identified If the battery is used the remaining battery capacity is displayed 3 1 3 LCD Brightness A...

Page 16: ...or lint free tissue Dust particulates can enter inside the protection sleeve and might result in a future fiber break or attenuation increase Make sure fiber is passed into the protection sleeve When...

Page 17: ...ouch anything 3 2 4 Loading Fiber to Splicer Open wind protector and sheath clamps Place prepared fiber onto v groove so that the fiber tip is located between the v groove edge and tip of electrode Ho...

Page 18: ...pping is detected the buzzer will sound and an error message warns the operator The splicing procedure pauses If no error message is displayed the below stated end face conditions are used for visual...

Page 19: ...e for details Splice loss may be improved in some cases by additional arc discharges Press ARC button for an additional arc discharge re arc Splice loss estimate and splice check are performed again S...

Page 20: ...leeve to verify no bubbles or debris dust is present in the sleeve 4 Menu Operation Press MENU button to enter splicer menu there are four main menus 1 Splice Mode Menu 2 Management Menu 3 Maintenance...

Page 21: ...mmended for splcing in most cases in which the splicer will automacially adjust splice parameters according to fiber type 2 Edit Splice Mode Splicing parameters in each splice mode can be modified In...

Page 22: ...An error message is displayed if the cleave angle of either the left or right fiber ends exceeds the selected threshold Loss Limit An error message is displayed if the estimated splice loss exceeds s...

Page 23: ...Tube heating conditions stored in heater mode can be edited or changed Editable parameters include Heat Time Heat Temp heating temperature and etc Heat Time will automatically adjust according to atmo...

Page 24: ...2 Heat Temp 60mm 60mm 36 sec 180 Finish Temp 90 1 Exit Select LR Heat Power Center Heat Power Heater Control Heater Mode Edit Long Cool Time 150 bit 15 sec 2 150 bit Heat Time Center side 1 2 3 4 Exit...

Page 25: ...s up to 5 000 splicing results In Splice Memory menu operator can review saved results or delete saved results 4 2 Management Menu This menu is used to change language and power save settings Press or...

Page 26: ...any key to turn back on the LCD monitor Splicer can also automatically turn off after certain period of time without operation 0 20 minutes adjustable 4 3 Maintenance Menu OFS 80 has the ability to p...

Page 27: ...r cleaver is well conditioned Core step Dust on v groove or fiber clamp chip Clean v groove and fiber clamp chip Core Curve Bad fiber end face quality Check if fiber cleaver is well conditioned Prefus...

Page 28: ...ber stuffing too small Perform Motor Calibration Prefuse power too high or prefuse time too long Decrease Prefuse Power and or Prefuse Time Fat Fiber stuffing too much Decrease Overlap and perform Mot...

Page 29: ...e parts e g electrodes Shineway Technologies Inc reserves the right to make changes to any of its products at any time without having to replace or change previously purchased units 6 3 Warranty Regis...

Page 30: ...ntact phone number email address and problem description Be sure to seal the packing box with exclusive tape Be sure to ship to your representative or the agent of the Company in a reliable way 6 5 Co...