18
Use DEF that is compliant with the ISO (International Organization for Standardization) 22241
standard defined for AUS 32, or the API (American Petroleum Institute) standards.
DEF, or other similar urea fluids, may be called AdBlue
depending on region.
AdBlue is a registered trademark of Verband der Automobilindustrie (VDA).
This generator is equipped with the SCR SYSTEM MONITOR.
The indicator lights up according to the control operation of the SCR system.
(1) DEF LEVEL
It shows the amount of DEF in the tank.
All lamps are lit when the amount reaches to the maximum level, and FULL is lit.
The lit lamp decreases as the amount of DEF in the tank reaches to EMPTY.
< Note >
The engine will shut down upon DEF gets empty.
When replenishing diesel fuel, check the amount of DEF in the tank, and replenish DEF as
necessary.
■
DEF LEVEL Lamp Action
LAMP
DEF
remaining amount
DEF LEVEL
DEF
REFILL DEF
NO POWER
(SHUTDOWN)
ESCAPE
MODE
Less than
100%
More than 75%
All Lamp
Turn ON
-
-
-
-
Less than
75%
More than 50%
4 Lamp
Turn ON
-
-
-
-
Less than
50%
More than 25%
3 Lamp
Turn ON
-
-
-
-
Less than
25%
More than 10%
2 Lamp
Turn ON
-
-
-
-
Less than
10%
More than 5%
1 Lamp
Turn ON
○
(Turn ON)
○
(Turn ON)
-
-
Less than
5%
More than 0%
1 Lamp
Slow Blinking
○
(Slow Blinking)
○
(Turn ON)
-
-
0%
(EMPTY)
All Lamp
Slow Blinking
○
(Quick Blinking)
○
(Turn ON)
○
(Turn ON)
-
0%
(ESCAPE MODE)
All Lamp
Slow Blinking
○
(Quick Blinking)
○
(Turn ON)
-
○
(Turn ON)
(2) PURGE Indicator
After certain length of operation time, SCR system automatically increase the temperature of
the exhaust gas, and purges inside the system, thereby maintaining the system function.
This lamp is lit up during purging.
Ⓡ
Ⓡ