13
5-1. Three-phase and Single-phase simultaneous Output
This generator is capable of generating three-phase and single-phase three-wire output
simultaneously. (Three-phase output terminal and single-phase three-wire output terminal are
equipped individually.)
Neither switching operation of output nor switching operation of wiring is needed.
Three-Phase and Single-Phase Three-Wire Output Terminal
< Note >
Refer to section “
7-2. Connecting Load Cables
” for Load Connections.
If using three-phase output simultaneously with a single-phase three-wire type output, use in
a range where the total current does not exceed the rated current.
5-2. Available Output Monitor
The available generated output for each output power source is displayed digitally.
< Note >
Consider the digitally displayed available output as an
approximate estimate. Be sure to thoroughly consider the
displayed value and the used load capacity when using a load
such as a motor with large starting capacity.
The displayed output capacity might not be correct values if
using a four-wire connection (single-phase using the N
terminal) for a three-phase output power source. Connect to a
single-phase/three-line type power source if using a
single-phase power source.
If “- -” is displayed for the available output, it means that usage
has exceeded the rated capacity. Immediately stop the
equipment being used and reduce the load capacity of the
equipment.
5. Equipment
Summary of Contents for DGK125F
Page 2: ......
Page 63: ...60 13 Generator Circuit Diagram ...
Page 64: ...61 14 Engine Electrical Circuit Diagram ...
Page 65: ...62 ...
Page 66: ...63 ...
Page 67: ......
Page 68: ... 2020 ...