41
Radiator Cap Cover
Radiator Cap
Inlet
Radiator Plate
Radiator
Drain Cock
Drain Plug
Sub Tank
MAX
MIN
(8) Change coolant
Remove the radiator plate first and open
the radiator cap cover.
Remove the radiator cap.
Loosen the radiator drain lever and the
drain plug on the engine side.
After draining finishes,
tighten the radiator drain
lever and the drain plug
on the engine side.
Drain the sub tank stay
and drain coolant in the
sub tank.
Reinstall the sub tank and fill coolant up to MAX
level.
Fill coolant into radiator up as far as the water inlet
level.
Tighten the radiator cap.
Close the radiator cap cover and
Reinstall the radiator plate.
<Caution>
Refer Coolant to
ᇹ
8-2. Checking Coolant/Water
ᇺ
.
2
3
4
5
6
7
9
1
Change
2 years or 1000 hours
8
Coolant Drain