  9.Specifi cations and Dimensions

  8. Support

  8.1 Repair and Calibration

Please contact your Shimpo dealer for information regarding the repair and calibration of your FGV-XY.

  8.2 Warranty

Nidec-Shimpo Corp. warrants, to the original purchaser of new products only, that this product shall be free from defects in workmanship and 

materials under normal use and proper maintenance for one year from the date of original purchase. See fi nal page for full warranty disclosure.

※ Dimension for FGP-0.2 ~ 0.5 is 141mm, FGP-100 is 149mm.

 

 

 

 

 

 

 

 

 

 

 

Model

FGV-0.5XY

FGV-1XY

FGV-2XY

FGV-5XY

FGV-10XY

FGV-20XY

FGV-50XY

FGV-100XY

FGV-200XY

Capacity

0.500lb

2.000 N

1.000lb

5.000 N

2.000lb

10.00 N

20.00 N

50.00 N

100.0 N

200.0 N

500.0 N

1000 N

200.0 g

500.0 g

1000 g

2.000 kg

5.000 kg

10.00 kg

20.00 kg

50.00 kg

100.0 kg

8oz

16oz

2 lb

5 lb

10 lb

20 lb

50 lb

100 lb

200 lb

Resolution

0.001lb

0.001 N

0.001lb

0.01 N

0.01 N

0.01 N

0.1 N

0.1 N

1 N

0.1 kg

1 kg

0.001 kg

0.001 kg

0.01 kg

0.01 kg

0.1 kg

0.01 oz

0.001 lb

0.001 lb

0.01 lb

0.01 lb

0.1 lb

0.1 lb

Units of Measure

                     lb / oz /g / N

Measurement 

Modes

Standard, Compression Peak, Tension Peak

Display Rate

User Selectable: 1, 2, 3, 5, 10, 20 times per second

Sampling Rate

1000 times per second

Accuracy

± 0.2% F.S.

Infl uence of 

temperature

Gain : ± 0.01 LOAD / Zero : ±0.01 / R.C. / Drift of zero point can be cancelled with tracking function.

Display

Main display: 4-digits 12mm high, Reversible
Units display: 3-digits 7mm high 

Other display: "LO BAT"(Low Battery Voltage), "BAT"(Battery Charging), "OVR"(Overload), "Peak"(Peak Hold)

Overload 

200% of Full Scale

150% F.S.

Tracking 

User Selectable (ON/OFF)

Output

USB

Allows communication between FGV-XY and ToriemonUSB via USB cable(included).

RS-232C

Allows communication between the FGV-XY and RS-232C devices.  RS-232C cable is an optional accessory.

Analog

± 1V, Accuracy is ± 50mV through a 12 bit D/A.  ZERO affects this output, and is updated at 1000 times/second. Load is >10k Ω

Overload/ 

Comparator

Open-collector output (Max DC30V/5mA).

Power

Rechargeable Nickel hydride battery or AC adapter/charger. Usable while charging.
Operating Time: Approximately 8 hours after a full charge. Charging Time: 16 Hours Max.

Auto Power Off

Default is 10 minutes.  Can be disbaled. Automatically disabled when connected to AC adapter.

Memory function

Continuous memory: 1000 data points, Single memory: 100 data points, Standard memory: 50 data points
Statistics functions (max, minimum, peak, average, standard deviation)

Comparator function

User Selectable: HI and LO

Temperature range

40° C (-32 

104° F)

Humidity range

35 

85% RH

Dimensions

147mm ※ (L)x 75mm (W) x 38mm(H)

Weight

Approx. 450g

Approx. 500g

Accessories 

(Included)

AC  adapter/charger,  carrying  case,  hook,  chisel,  flat  head,  notched  head,  hanger,  cone  head,  thread  Adapter, 
extension rod, USB cable

Application 

software

Application software (USB version): Available at www.shimpoinst.com/software for free.

lb / kg / N

Summary of Contents for FGV Series

Page 1: ...ore using your gauge FGV 0 5 1 2 5 10 20 50 100 200 XY NIDEC SHIMPO CORPORATION REVERSE PEAK PEAK UNIT UNIT ZERO ZERO POWER POWER MEMORY MEMORY FGV 10XY 10 00lb 5 000kg 50 00N REVERSE PEAK PEAK UNIT U...

Page 2: ...re hazard Warning Caution Safety Precautions Use appropriate safety equipment while performing tests with the FGV XY Use of a broken deformed or damaged attachment or gauge is prohibited Weighing lar...

Page 3: ...n permanent damage and inaccurate measurements To ensure consistent accuracy it is recommended that your FGV XY be calibrated at a minimum of once per year Contact your Shimpo dealer for information r...

Page 4: ...6 1 Setting the Memory Mode 16 5 6 2 Recording Memory Data 17 5 6 2 1 Continuous Mode 17 5 6 2 2 Single Mode 17 5 6 2 3 Standard Mode 17 5 7 Reviewing Memory Data 18 5 7 1 Continuous Mode Memory 18 5...

Page 5: ...wnloaded to PC via USB 5 9 USB Communication 1000 points of data storage 5 6 Memory Comparator feature for pass fail testing 5 5 Comparator Broad range of capacities 2 000N 200 0gf 8oz 1000N 100 0kgf...

Page 6: ...sing ZERO in Peak mode will clear the current peak value 6 MEM Press MEM in standard mode to activate measurement recording 7 POWER Press POWER to turn gauge on and off 8 AC Adapter Port Port used for...

Page 7: ...nit is in Peak mode The presence of con rms negative Peak mode Newton Kilogram Gram When displaying statistical data in memory mode the following indictors are shown The polarity setting f01 will dete...

Page 8: ...utomatically and BAT will show on the LCD Charging will stop automatically and BAT will disappear from the LCD Charge time Up to 16 Hours Operating time Approximately 8 Hours 2 To conserve battery lif...

Page 9: ...Repeat the process to turn Track ing back on Instead of oFF SEt will be displayed Splash Screen Tracking OFF Tracking ON Standard Measuring Mode Release PEAK and UNIT after the display shows SEt or oF...

Page 10: ...is updated The update times available are 1 2 3 5 10 and 20 times a second Press UNIT to cycle through the settings PEAK to save and move to the next function or ZERO to save and nish 1 time sec 2 tim...

Page 11: ...Press UNIT to cycle through the available settings ZERO Save the current setting and return to the standard measuring mode PEAK Save the current setting and move to f06 Response Time 3msec Response Ti...

Page 12: ...splay UNIT Cycles through the statistical data for the current memory block PEAK Returns to Standard mode ZERO Deletes one memory block Hold ZERO to delete all memory data MEM Advances to the next mem...

Page 13: ...easuring and remove the load immediately to avoid permanent damage to the gauge Any measurements taken in the overload range are not accurate Tare is automatically performed when the gauge is rst powe...

Page 14: ...Value for the HI limit 0 Comparator LO limit LO Value for the LO limit 0 Memory mode MEM Memory mode Standard Single Continuous Std When HI and LO are set to 00 00 the Comparator function is disabled...

Page 15: ...alue negative peak value average value standard deviation Single memory Allows the recording of up to 100 data points Every time MEM is pressed the value shown on the display is memorized If the unit...

Page 16: ...nt values X i n Standard deviation DEV Standard deviation of the recorded measurement values Xi X 2 n Positive peak value Largest value in the positive direction This value is sampled at 1000 times se...

Page 17: ...ing Comparator LO limit setting PEAK There are following items are found in the Comparator Memory mode settings Item Display Content Default factory setting Comparator HI limit setting HI Displays the...

Page 18: ...nt mode press MEM The letter M will appear to show that one data point has been recorded 2 If 100 data points have been collected the screen will show FULL and return to standard measurement mode Key...

Page 19: ...rement value of that block 2 Press MEM to review the previous data block recorded 3 Press UNIT to cycle through the available recorded statistics In Continuous mode the available statistics are as fol...

Page 20: ...urn power off PEAK PEAK ZERO MEM UNIT 1 Hold down MEM 2 Press POWER PEAK PEAK ZERO MEM UNIT 3 Release POWER MEM Exits statistic mode and returns to memory blocks PEAK Transfers the recorded memory dat...

Page 21: ...display The unit will alternate between showing the data block number and the recorded measurement value of that block 2 Press MEM to review the previous data block recorded 3 Press UNIT to cycle thro...

Page 22: ...peration Display Turn power off PEAK PEAK ZERO MEM UNIT 1 Hold down MEM 2 Press POWER PEAK PEAK ZERO MEM UNIT 3 Release POWER MEM Exits statistic mode and returns to memory blocks PEAK Transfers the r...

Page 23: ...his is covered in greater detail in the next section 5 7 3 2 4 Press PEAK to output the recorded memory via RS 232C Refer to section 6 2 regarding RS232C communication Key operation Display Turn power...

Page 24: ...peak value 3 Press MEM to exit to the recorded measurement values 4 Press PEAK key to output the recorded memory via RS 232C Refer to section 6 2 regarding RS232C communication 5 8 Clearing the Memor...

Page 25: ...9 1 Features of ToriemonUSB 5 9 2 Download ToriemonUSB The USB port allows you to connect your FGV XY via the supplied USB cable to your PC Our free software ToriemonUSB allows you to capture data di...

Page 26: ...po dealer for information regard ing optional cables and accessories Always leave pin 7 unconnected 6 2 RS 232C Output The RS 232C data connection allows control from external devices and data transfe...

Page 27: ...cr Request continuous transmission of measurement data 10 times second BB cr NA xxxxxx cr BB1 cr Request continuous transmission of measurement data 20 times second BB1 cr NA xxxxxx cr BB2 cr Request...

Page 28: ...rigger Common For Pins 8 and 9 30V 5mA Maximum Overload Output When the overload condition is triggered the corresponding overload output turns on This can be used to stop a motorized test stand or an...

Page 29: ...ible with the FGV XY Toriemon is only compatible with DART and JAVELIN series gauges Download ToriemonUSB from the following website Questions Explanation Reference How long should my FGV XY s bat ter...

Page 30: ...tracking function Display Main display 4 digits 12mm high Reversible Units display 3 digits 7mm high Other display LO BAT Low Battery Voltage BAT Battery Charging OVR Overload Peak Peak Hold Overload...

Page 31: ...r the attachments included with the FGV 5 50XY M6 Please contact your Shimpo dealer for information on the attachments included with 0 5 1 2 and 200 models M6 26 70 3 5 M6 8 43 R 4 M6 26 70 M6 26 70 s...

Page 32: ...R OR REPLACE the defective product or part at Shimpo Instrument s option Shimpo Instruments reserves the right to satisfy warranty obligation in full by reimbursing Buyer for all payments made to Shim...

Reviews: