background image

-21-

  5.7.2.2 Statistics Data

1. When in memory mode, UNIT will cycle through the available statistics data.

2. Each press of UNIT will switch between the following items: positive maximum value, negative maximum value,

positive minimum value, negative minimum value, average value, standard deviation. 

3. Press MEM to exit to the recorded measurement values.

4. Press PEAK key to output the recorded memory via RS-232C.  Refer to section 6.2 regarding RS232C communication.

Key operation

Display

Turn power off

PEAK

PEAK

ZERO

MEM

UNIT

  1. Hold down MEM

     2. Press POWER

PEAK

PEAK

ZERO

MEM

UNIT

  3. Release POWER

MEM

Exits statistic mode, and returns to memory blocks.

PEAK

Transfers the recorded memory data via RS232C, and exits memory mode.

Powers off the FGV-XY.

Positive Maximum

Negative Maximum

Positive Minimum

Standard deviation

UNIT

UNIT

UNIT

UNIT

UNIT

UNIT

Negative Minimum

Average

Memory block

Recorded Value

Display statistical data

UNIT

Release MEM after "CNT" 

has displayed.

MEM

1.

2.

MEMORY

MEMORY

MEMORY

MEMORY

POWER

POWER

UNITUNIT

UNITUNIT

UNITUNIT

UNITUNIT

UNITUNIT

UNITUNIT

UNITUNIT

MEMORY

MEMORY

MEMORY

MEMORY

POWER

POWER

PEAKPEAK

Summary of Contents for FGV Series

Page 1: ...ore using your gauge FGV 0 5 1 2 5 10 20 50 100 200 XY NIDEC SHIMPO CORPORATION REVERSE PEAK PEAK UNIT UNIT ZERO ZERO POWER POWER MEMORY MEMORY FGV 10XY 10 00lb 5 000kg 50 00N REVERSE PEAK PEAK UNIT U...

Page 2: ...re hazard Warning Caution Safety Precautions Use appropriate safety equipment while performing tests with the FGV XY Use of a broken deformed or damaged attachment or gauge is prohibited Weighing lar...

Page 3: ...n permanent damage and inaccurate measurements To ensure consistent accuracy it is recommended that your FGV XY be calibrated at a minimum of once per year Contact your Shimpo dealer for information r...

Page 4: ...6 1 Setting the Memory Mode 16 5 6 2 Recording Memory Data 17 5 6 2 1 Continuous Mode 17 5 6 2 2 Single Mode 17 5 6 2 3 Standard Mode 17 5 7 Reviewing Memory Data 18 5 7 1 Continuous Mode Memory 18 5...

Page 5: ...wnloaded to PC via USB 5 9 USB Communication 1000 points of data storage 5 6 Memory Comparator feature for pass fail testing 5 5 Comparator Broad range of capacities 2 000N 200 0gf 8oz 1000N 100 0kgf...

Page 6: ...sing ZERO in Peak mode will clear the current peak value 6 MEM Press MEM in standard mode to activate measurement recording 7 POWER Press POWER to turn gauge on and off 8 AC Adapter Port Port used for...

Page 7: ...nit is in Peak mode The presence of con rms negative Peak mode Newton Kilogram Gram When displaying statistical data in memory mode the following indictors are shown The polarity setting f01 will dete...

Page 8: ...utomatically and BAT will show on the LCD Charging will stop automatically and BAT will disappear from the LCD Charge time Up to 16 Hours Operating time Approximately 8 Hours 2 To conserve battery lif...

Page 9: ...Repeat the process to turn Track ing back on Instead of oFF SEt will be displayed Splash Screen Tracking OFF Tracking ON Standard Measuring Mode Release PEAK and UNIT after the display shows SEt or oF...

Page 10: ...is updated The update times available are 1 2 3 5 10 and 20 times a second Press UNIT to cycle through the settings PEAK to save and move to the next function or ZERO to save and nish 1 time sec 2 tim...

Page 11: ...Press UNIT to cycle through the available settings ZERO Save the current setting and return to the standard measuring mode PEAK Save the current setting and move to f06 Response Time 3msec Response Ti...

Page 12: ...splay UNIT Cycles through the statistical data for the current memory block PEAK Returns to Standard mode ZERO Deletes one memory block Hold ZERO to delete all memory data MEM Advances to the next mem...

Page 13: ...easuring and remove the load immediately to avoid permanent damage to the gauge Any measurements taken in the overload range are not accurate Tare is automatically performed when the gauge is rst powe...

Page 14: ...Value for the HI limit 0 Comparator LO limit LO Value for the LO limit 0 Memory mode MEM Memory mode Standard Single Continuous Std When HI and LO are set to 00 00 the Comparator function is disabled...

Page 15: ...alue negative peak value average value standard deviation Single memory Allows the recording of up to 100 data points Every time MEM is pressed the value shown on the display is memorized If the unit...

Page 16: ...nt values X i n Standard deviation DEV Standard deviation of the recorded measurement values Xi X 2 n Positive peak value Largest value in the positive direction This value is sampled at 1000 times se...

Page 17: ...ing Comparator LO limit setting PEAK There are following items are found in the Comparator Memory mode settings Item Display Content Default factory setting Comparator HI limit setting HI Displays the...

Page 18: ...nt mode press MEM The letter M will appear to show that one data point has been recorded 2 If 100 data points have been collected the screen will show FULL and return to standard measurement mode Key...

Page 19: ...rement value of that block 2 Press MEM to review the previous data block recorded 3 Press UNIT to cycle through the available recorded statistics In Continuous mode the available statistics are as fol...

Page 20: ...urn power off PEAK PEAK ZERO MEM UNIT 1 Hold down MEM 2 Press POWER PEAK PEAK ZERO MEM UNIT 3 Release POWER MEM Exits statistic mode and returns to memory blocks PEAK Transfers the recorded memory dat...

Page 21: ...display The unit will alternate between showing the data block number and the recorded measurement value of that block 2 Press MEM to review the previous data block recorded 3 Press UNIT to cycle thro...

Page 22: ...peration Display Turn power off PEAK PEAK ZERO MEM UNIT 1 Hold down MEM 2 Press POWER PEAK PEAK ZERO MEM UNIT 3 Release POWER MEM Exits statistic mode and returns to memory blocks PEAK Transfers the r...

Page 23: ...his is covered in greater detail in the next section 5 7 3 2 4 Press PEAK to output the recorded memory via RS 232C Refer to section 6 2 regarding RS232C communication Key operation Display Turn power...

Page 24: ...peak value 3 Press MEM to exit to the recorded measurement values 4 Press PEAK key to output the recorded memory via RS 232C Refer to section 6 2 regarding RS232C communication 5 8 Clearing the Memor...

Page 25: ...9 1 Features of ToriemonUSB 5 9 2 Download ToriemonUSB The USB port allows you to connect your FGV XY via the supplied USB cable to your PC Our free software ToriemonUSB allows you to capture data di...

Page 26: ...po dealer for information regard ing optional cables and accessories Always leave pin 7 unconnected 6 2 RS 232C Output The RS 232C data connection allows control from external devices and data transfe...

Page 27: ...cr Request continuous transmission of measurement data 10 times second BB cr NA xxxxxx cr BB1 cr Request continuous transmission of measurement data 20 times second BB1 cr NA xxxxxx cr BB2 cr Request...

Page 28: ...rigger Common For Pins 8 and 9 30V 5mA Maximum Overload Output When the overload condition is triggered the corresponding overload output turns on This can be used to stop a motorized test stand or an...

Page 29: ...ible with the FGV XY Toriemon is only compatible with DART and JAVELIN series gauges Download ToriemonUSB from the following website Questions Explanation Reference How long should my FGV XY s bat ter...

Page 30: ...tracking function Display Main display 4 digits 12mm high Reversible Units display 3 digits 7mm high Other display LO BAT Low Battery Voltage BAT Battery Charging OVR Overload Peak Peak Hold Overload...

Page 31: ...r the attachments included with the FGV 5 50XY M6 Please contact your Shimpo dealer for information on the attachments included with 0 5 1 2 and 200 models M6 26 70 3 5 M6 8 43 R 4 M6 26 70 M6 26 70 s...

Page 32: ...R OR REPLACE the defective product or part at Shimpo Instrument s option Shimpo Instruments reserves the right to satisfy warranty obligation in full by reimbursing Buyer for all payments made to Shim...

Reviews: