OMNI-Test Laboratories, Inc.
PR - Proportional Rate Variation
ASTM E2515 equation (16)
Where:
θ = Total sampling time, min
θ
i
=
Length of recording interval, min
V
mi
=
Volume of gas sample measured by the dry gas meter during the “ith”
time interval, dcf
V
m
=
Volume of gas sample as measured by dry gas meter, dcf
V
si
=
Average gas velocity in the dilution tunnel during the "ith" time interval, ft/sec
V
s
=
Average gas velocity in the dilution tunnel, ft/sec
T
mi
=
Absolute average dry gas meter temperature during the "ith" time interval,
o
R
T
m
=
Absolute average dry gas meter temperature,
o
R
T
si
=
Absolute average gas temperature in the dilution tunnel during the "ith" time interval,
o
R
T
s
=
Absolute average gas temperature in the dilution tunnel,
o
R
Sample calculation (for the first 1 minute interval of Train 1):
361 x
0.154
x
12.83
x (
114.0 + 460 ) x ( 81.9 + 460
)
1
x
59.52
x
13.07
x (
93.6
+ 460 ) x ( 75.0 + 460
)
PR =
96 %
x 100
)
(
PR =
100
=
s
mi
si
m
i
si
m
s
mi
T
T
V
V
T
T
V
V
PR
Control No. P-SFDK-0002, Effective date: 5/06/2016
File - Run 1, Tab - Example Calculations
66 of 194
66 of 194
Summary of Contents for GF55
Page 29: ...29 of 194 29 of 194...
Page 30: ...30 of 194 30 of 194...
Page 31: ...31 of 194 31 of 194...
Page 32: ...32 of 194 32 of 194...
Page 33: ...33 of 194 33 of 194...
Page 38: ...38 of 194 38 of 194...
Page 39: ...39 of 194 39 of 194...
Page 40: ...40 of 194 40 of 194...
Page 41: ...41 of 194 41 of 194...
Page 42: ...42 of 194 42 of 194...
Page 45: ...1 19 2018 45 of 194 45 of 194...
Page 48: ...1 19 2018 48 of 194 48 of 194...
Page 49: ...49 of 194 49 of 194...
Page 50: ...50 of 194 50 of 194...
Page 52: ...52 of 194 52 of 194...
Page 53: ...53 of 194 53 of 194...
Page 114: ...43 MERIDIAN Components May 2015 4 11 1 17 6 2 12 7 5 3 39 Parts Diagram Components...
Page 117: ...46 Notes...
Page 155: ...36 MERIDIAN CAST IRON Components May 2015 4 11 1 10 6 2 9 7 5 3 8 Parts Diagram Components...
Page 157: ...38 Notes...