15
Installation
D
imenSionS
:
Figure 14: Meridian Cast Iron Dimensions.
Minimum
6" (150mm)
Figure 15: Meridian Cast Iron on
Floor Protection.
Back wall
Side wall
Adjacent
wall
2"
(51mm)
3" (76mm)
6"
(152mm)
c
LeaRanceS
to
c
ombuStibLeS
:
These dimensions are minimum clearances but it is recommended that you ensure sufficient room for
serving, routine cleaning and maintenance.
Figure 16: Minimum Clearances to Combustibles for
Meridian Cast Iron.
This pellet stove requires floor protection. The floor protection must be non-combustible, extending
beneath the stove the full width and depth of the unit including 6“ (150 mm) in front for ember protection
30 1/2"
(775mm)
30 5/8"
(778mm)
25 1/2"
(648mm)