8
only
)
At frequency range, the Meter defaults to frequency counter.
Press Hz% to enter duty cycle mode, the Meter beeps, press
Hz% again return to frequency counter function, the Meter
beeps.
At AC voltage or AC current range, press Hz% to start
frequency counter, the Meter beeps. Press Hz% again to
enter duty cycle mode, the Meter beeps, and press it third
time the Meter return to AC voltage or AC current measuring
mode. Then the pressing actions will repeat above turns.
At AC voltage or AC current measuring mode press Hz%, the
autoranging turn off and the Meter stay in the range when
Hz% is pressed. For this case, the sensitivity and measuring
range as below:
Table 1. Sensitivity of frequency measurement
Range Sensitivity
Measuring
Range
4V
≥
1.0V 5
~
10kHz
40V
≥
5.0V 5
~
20kHz
400V
≥
45V 45
~
4kHz
1000/
~
750V
≥
420V 45
~
1.6kHz
mA
≥
45mA 5
~
5kHz
A
≥
4A 45
~
1kHz
RANGE button
(Auto Ranging/Manual Ranging)
The Meter has both manual range and autorange options.