Timming ON /OFF Setting
In default state, long press " " for 3 seconds to enter Timing Setting state.In the
state of Timming Setting ,press " " again
,
the hour numbers for timing ON flash,
press " " or " " to adjust the hour for timming ON setting.
After setting the hour for timing ON, press " " once again, the minute number for
timming ON flash, press " " or" " to adjust the minute for timming ON.
After setting the minute for timming ON, press " " once again
,
to enter the hour
setting of timming OFF;After setting the timming OFF hour and minute, press " "
again
,
to confirm current setting and return to default state. In the state of Timming
Setting, press " " once
,
it will clear timming ON /OFF setting and return to default
state. In the state of Timming Setting, if not pressing any button within 5 seconds,it will
auto confirm the current timming setting and return to default state.In the state of
Timming Setting, press " "once, it will confirm the current timming setting and
return to default state and change the ON /OFF state.
Keyboard Lock & Unlock
In default state, long press " " and " " for 3 seconds AT THE SAME TIME
,
vibrator "bee" once , the keyboard will be locked.In the state of Locked, long press
" " and " " for 3seconds
,
vibrator "bee" for once, the keyboard will be unlocked.
Back Up Memory After Power Resumption
When the heat pump is working in normal state and electricity power cut off suddently,
the system will run in the last setting record after power resumption.
6
SWIMMING POOL HEAT PUMP
Timming ON
Timming OFF
Keyboard Lock
Please refer to the wiring diagram for the location of S1 and S2 switch.
1) Heat pump turns on when S1 or S2 switch has well connected. While S1 or S2 has
connected, suddenly press the off button on the LCD controller. Heat pump will stop
for 3 minutes. However, heat pump continues to turn on if S1 or S2 still has been
connected after 3 minutes.
2) The Timer function is out of validity either S1 or S2 switch has connected.
3) Heat pump turns off when S1 or S2 switch is disconnected. Meanwhile, need to use
LCD controller to turn on /off the heat pump.
Setting about S1 & S2 switch
S2 Switch---Long distance demand for cooling
S1 Switch---Long distance demand for heating