34
Image Projection (Continued)
R
On-screen display
GEOMETRIC ADJUSTMENT
Geometric Adjustment
2
Press
c
KEYSTONE on the re-
mote control repeatedly until
“GEOMETRIC ADJUSTMENT” is
displayed.
3
Press
P
,
R
,
O
or
Q
to move the
position for the upper left of the
image.
• Adjust the screen until the displayed red
arrows line up in the upper left.
4
Press
i
ENTER to set the posi-
tion.
• The arrow in the upper right turns red.
5
Repeat the same procedure with
the positions for the upper right,
lower right and lower left of the
image.
• When you press
e
RETURN at this point,
you will return to the previous screen.
• If you press
e
RETURN before adjust-
ing the upper left corner, the Reset Con-
firmation screen displays.
•
When you confirm the lower left posi-
tion, the screen adjustments will be set
and the “GEOMETRIC ADJUSTMENT”
mode will end.
1
Adjust the focus, size, and projec-
tion angle so that the screen
edges line up into the blue area.
• Line up the screen edges into the blue
area as closely as possible.
Adjust upper left corner
GEOMETRIC ADJUSTMENT
ADJUST
NEXT
RESET
END
• The placement of the screen and the projector
may result in the image aspect ratio becoming
slightly distorted.
• Try “H&V KEYSTONE” when “GEOMETRIC
ADJUSTMENT” does not fully correct trapezoi-
dal distortion.
Note
Blue
area
Screen
Upper Left
Upper Right
Lower Left
Lower Right
• When adjusting a 4:3-aspect-ratio input sig-
nal to a 4:3-aspect-ratio screen, correct the
trapezoidal distortion by setting “RESIZE” to
“STRETCH” (16:9).
Info
XV-Z3000_US_EN_h
06.2.9, 10:43 AM
34