Appendix
-97
Optional
accessories
Lamp unit 1
AN-PH7LP1
Removing and Installing
the Lamp Unit
Info
•
Ensure the lamp unit is removed using the
handle. Ensure the glass surface of the
lamp unit or the inside of the projector are
not touched.
•
To avoid injury to yourself and damage to
the lamp, make sure you carefully follow
the steps below.
•
Do not loosen other screws except for the
lamp unit cover and lamp unit.
(Only the silver screws are loosened.)
1
Press
on the projector or
on the remote control to put
the projector into standby mode.
•
Wait until the cooling fan stops.
Warning!
•
Do not remove the lamp unit from the
projector right after use. The lamp and
parts around the lamp will be very hot
and may cause burn or injury.
2
Disconnect the power cord.
•
Unplug the power cord from the AC
socket.
•
Leave the lamp until it has fully cooled
down (about 1 hour).
3
Remove the lamp unit cover.
•
Loosen the user service screw (
1
) that
secures the lamp unit cover. Remove the
lamp unit cover (
2
).
STANDBY button
Power cord
1
2
User service screw
Lamp unit 2
AN-PH7LP2
Summary of Contents for XG-PH70X - XGA DLP Projector
Page 110: ...SHARP CORPORATION ...