ER-A7RS CON3
S1-1
S1-2
S1-3
CHANNEL
0
0
0
Invalid
0
0
1
CHANNEL 1: Do not set this
(Reserved for
standard RS)
0
1
0
CHANNEL 2: Do not set this
(Reserved for
standard RS)
0
1
1
CHANNEL 3
1
0
0
CHANNEL 4
1
0
1
CHANNEL 5
1
1
0
CHANNEL 6
1
1
1
CHANNEL 7: Do not set this
(Reserved for
internal printer)
ER-A7RS CON4
S1-4
S1-5
S1-6
CHANNEL
0
0
0
Invalid
0
0
1
CHANNEL 1: Do not set this
(Reserved for
standard RS)
0
1
0
CHANNEL 2: Do not set this
(Reserved for
standard RS)
0
1
1
CHANNEL 3
1
0
0
CHANNEL 4
1
0
1
CHANNEL 5
1
1
0
CHANNEL 6
1
1
1
CHANNEL 7: Do not set this
(Reserved for
internal printer)
2
Terminating procedure
Press the Touch panel to terminate the check.
2) CH1 Check
1
Check content
When the channel is not set, an error display is made
(ERROR:CH1). When the channel is set, the following check is
performed.
•
Control signal check
ERn
RSn
DRn
CIn
CDn
CSn
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
The read check of the above inputs and the interruption check
of CS, CI, and CD are performed.
In the read check, ER and RS are changed over in the above
sequence and the logic states of DR, CI, CD, and CS are
checked.
If the logic differs from that in the table, an error display is
made.
"ON" in the table means Active LOW, and "OFF" means Active
HIGH.
In the interruption check, an interruption of CS, CI, or CD is
allowed one by one. (MASK is canceled.)
If an interruption is not made when each signal is active, or if
an interruption is made when each signal is not active, an error
display is made.
The above check is repeated four cycles.
•
Data transfer check
The loop back data (256 bytes) of 00H
∼
0FFH are used for
data transfer check. The baud rate is set to 38400BPS.
•
Timer check (RS232 on board timer)
Before performing the check, set the timer to TCVDT start and
5ms. Then perform the following procedure.
*
During execution of the check, TRQ- must not be
generated.
*
After 5ms from completion of the check, TRQ- must be
generated.
2
Display
RS232 CH1 Check
ER-DR : ERROR!!
All the contents of an error must be displayed.
ERROR
No.
ERROR display
ERROR content
1
ER-DR:ERROR
ER-DR LOOP ERROR
2
ER-CI:ERROR
ER-CI LOOP ERROR
3
RS-CD:ERROR
RS-CD LOOP ERROR
4
RS-CS:ERROR
RS-CS LOOP ERROR
5
CI INT:ERROR
CI interruption is not made.
6
CD INT:ERROR
CD interruption is not made.
7
CS INT:ERROR
CS interruption is not made.
8
TXEMP:ERROR
TXEMP is not set.
9
TXEMP INT:ERROR
TXEMP interruption is not made.
10
TXRDY:ERROR
TXRDY interruption is not made.
11
TXRDY INT:ERROR
TXRDY interruption is not made.
12
RCVRDY:ERROR
RCVRDY is not set.
(Reception enabled. TR-Q is
generated during check)
13
RCVRDY INT:ERROR RCVRDY interruption is not
made.
14
SD-RD:ERROR
SD-RD LOOP ERROR
(DATA ERROR)
15
SD-RD:ERROR
SD-RD LOOP ERROR (DATA
ERROR, FRAMING ERROR, etc.)
16
TIMER:ERROR
TIMER ERROR (TMRQ is not set
after completion of check.)
17
TIMER INT:ERROR
TRQ-1 interruption is not made.
3
Terminating procedure
Press the Touch panel to terminate the check.
3) CH2 Check
1
Check content
The check procedure, the display, and the terminating procedure
are the same as CH1 Check.
4) CH3 Check
1
Check content
The check procedure, the display, and the terminating procedure
are the same as CH1 Check.
5) CH4 Check
1
Check content
The check procedure, the display, and the terminating procedure
are the same as CH1 Check.
6) CH5 Check
1
Check content
The check procedure, the display, and the terminating procedure
are the same as CH1 Check.
6 – 5