STEP-BY-STEP INSTALLATION GUIDE
C. RECIRCULATING (NON-VENTED DUCTLESS)
See page 17.
A. OUTSIDE TOP EXHAUST (VERTICAL DUCT) DEFAULT
Installation overview
A1. Attach the mounting plate to the wall
A2. Use Top Cabinet Template for preparation of top cabinet
A3. Check for proper damper operation
A4. Mount the microwave oven
A5. Adjust the exhaust adapter
A6. Connect ductwork
A1.
ATTACH MOUNTING PLATE TO THE WALL
Attach the mounting plate to the wall using the wing nuts and toggle
bolts (
3
⁄
16
" x 3" / 0.5 x 7.6 cm). At least one lag screw must be used
to attach the mounting plate to a wall stud.
1.
Insert the toggle bolts (
3
⁄
16
" x 3" / 0.5 x 7.6 cm) into the mounting
plate through the holes designed to go into drywall and attach
the wing nuts to
3
⁄
4
" (1.9 cm) onto each toggle bolt (
3
⁄
16
" x 3" /
0.5 x 7.6 cm).
2.
Place the mounting plate against the wall and insert the wing nuts
into the holes in the wall to mount the plate.
CAUTION
Be careful to avoid pinching fingers between the
back of the mounting plate and the wall.
3.
Tighten all bolts. Pull the mounting plate away from the wall to
help tighten the bolts.
5
/
8
"
Wall
Toggle
Bolt
Wing nut
Bolt end
Spacing for toggles more
than wall thickness