53
E
Controlling the Monitor with a computer (RS-232C)
Initialization/Functional Restriction Setting (FUNCTION) menu
Function
Command Direction
Parameter
Reply
Control/Response contents
*
ALL RESET
RSET
W
0-1
0: ALL RESET 1, 1: ALL RESET 2
-
ADJUSTMENT LOCK
ALCK
WR
0-2
0-2 0: OFF, 1:ON 1, 2:ON 2
●
ADJUSTMENT LOCK TARGET
ALTG
WR
0-2
0-2 0: REMOTE CONTROL, 1: MONITOR BUTTONS, 2: BOTH
○
OSD DISPLAY
LOSD
WR
0-2
0-2 0: ON 1, 1: OFF, 2: ON 2
LED
OFLD
WR
0-1
0-1 0: ON, 1: OFF
TEMPERATURE ALERT
TALT
WR
0-2
0-2 0: OFF, 1: OSD & LED, 2: LED
STATUS ALERT
SALT
WR
0-2
0-2 0: OFF, 1: OSD & LED, 2: LED
POWER BUTTON
PBTN
WR
0-1
0-1 0: MONITOR, 1: EXT. CONTROLLER
EXTERNAL CONTROLLER INPUT
PCIP
WR
0-3, 5, 6
0-3, 5, 6 0: D-SUB, 1: DisplayPort1, 2: HDMI1, 3: HDMI2, 5: HDMI3, 6: DisplayPort2
(“ERR” when MONITOR is selected for POWER BUTTON.)
SIGNAL RESPONSE LEVEL
HDUC
WR
1-200
1-200
Others
Function
Command Direction
Parameter
Reply
Control/Response contents
*
SIZE (Screen size selection)
WIDE
WR
1-5
1-5 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2
○
INFORMATION
Model
INF1
R
Value
●
Serial no.
SRNO
R
Value
Temperature sensor
DSTA
R
0 Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in standby mode
2 Internal temperature abnormal occurred (To delete the information of temperature
abnormal, turn off the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is dimmed
4 Temperature sensor abnormal
Temperature acquisition
ERRT
R
Value Returns the temperature at the temperature sensors.
Indicates a temperature sensor abnormality when “126” is returned.
○
Cause of last standby mode
STCA
W
0
Initialization
●
R
0 No detectable error has occurred
1 Standby mode by POWER button or MONITOR OFF button
2 Main power off by the main power switch
3 Standby mode by RS-232C or LAN
4 Input signal waiting mode by No Signal
6 Standby mode by abnormal temperature
8 Standby mode by SCHEDULE setting
9 Standby mode by DDC/CI
10 Standby mode by HDMI CEC
20 Standby mode by OFF IF NO OPERATION setting
Touch operation valid/invalid
TPEN
WR
0-1
0-1 0: Invalid, 1: Valid
“ERR” when TOUCH INPUT SELECT is set to INVALID or the touch panel is not
connected.
-
FREEZE
FRMD
WR
0-1
0-1 0: FREEZE release, 1: FREEZE execute
Commands for setting of the GAMMA user data
Function
Command Direction
Parameter
Reply
Control/Response contents
*
Red gamma data transfer
UGRW
W
aaxxxx ··· xxxxcc
(xxxx: 32 pieces)
aa: 01-16
xxxx: 0000-1023
cc: 00-FF
aa: Block number
xxxx: 32 pieces of user data
cc: Checksum (ASCII data) of the block number and user data
○
Green gamma data transfer
UGGW
W
Blue gamma data transfer
UGBW
W
Red gamma data read
UGRR
W
1-16 xxxx ··· xxxx
(xxxx: 32 pieces)
xxxx: 0000-1023
xxxx: User data of 32 pieces
Green gamma data read
UGGR
W
1-16
Blue gamma data read
UGBR
W
1-16
User data initialize
UGRS
W
0
Initialize the user data.
User data save
UGSV
W
0
Save the user data in the monitor.