43
E
You can return the settings to their factory-preset values and
restrict operations.
1. Press the FUNCTION button, and then press the MENU
button within 10 seconds.
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲▲▲▲▲
▲▲
OFF
UNLOCKED
ON 1
ON
LED
OFF
FUNCTION
ALL RESET
ADJUSTMENT LOCK
ADJUSTMENT LOCK TARGET
RS-232C/LAN
OSD DISPLAY
LED
TEMPERATURE ALERT
STATUS ALERT
OK:[ENTER] END:[RETURN]
MONITOR
1
POWER BUTTON
EXTERNAL CONTROLLER INPUT
SIGNAL RESPONSE LEVEL
2. Select and set the items.
ALL RESET
Resets the settings to the factory default settings.
Press the ENTER button, select the resetting method,
and then press the ENTER button.
ALL RESET 1 ...Resets all the settings to the factory
default settings.
ALL RESET 2 ...Returns all settings to the factory default
settings except for the following items:
LAN SETUP, RS-232C/LAN SELECT,
REMOTE No., BAUD RATE,
NETWORK, MAIL, SERVICE &
SUPPORT, and SNMP. (See page 35,
and pages 58 to 61.)
ADJUSTMENT LOCK
You can disable operations on the monitor and the
remote control unit that use buttons.
OFF ....Enables operation.
ON 1 ...Disables all operations other than turning power
on/off and FUNCTION.
ON 2 ...Only the FUNCTION operation is enabled.
Disables all operations other than FUNCTION
(not even power on/off).
ADJUSTMENT LOCK TARGET
Sets the target to prohibit operation of with
ADJUSTMENT LOCK.
REMOTE CONTROL ..... Prohibits remote control
operation
MONITOR BUTTONS ... Prohibits monitor button
operation
BOTH ............................. Prohibits remote control and
monitor button operation
RS-232C/LAN
Specifies whether to allow control via RS-232C or LAN.
(See pages 44 and 54.)
Initialization (Reset)/Functional Restriction Setting (FUNCTION)
OSD DISPLAY
Shows/hides the menu, modes and messages.
The FUNCTION screen cannot be hidden.
ON 1 .............. Shows all menus, modes and messages.
ON 2 .............. Hides messages automatically displayed
by the display. Shows messages during
operation.
OFF ............... Hides all menus, modes and messages.
LED
Specifies whether to light the power LED.
TEMPERATURE ALERT
Selects the notification method for an abnormal
temperature.
OFF ............... Do not notify about an abnormal
temperature.
OSD & LED ... When an abnormal temperature is
detected, the power LED flashes
in orange and blue alternately and
the screen displays a message:
TEMPERATURE.
LED................ When an abnormal temperature is
detected, the power LED flashes in
orange and blue alternately.
STATUS ALERT
Selects the notification method for a hardware error.
OFF ............... Do not notify about the error.
OSD & LED ... When a hardware error is detected, the
power LED illuminates in blue and orange
alternately and the screen displays a
message: STATUS [xxxx].
LED................ When a hardware error is detected, the
power LED illuminates in blue and orange
alternately.
POWER BUTTON
Normally, leave this setting as MONITOR.
When using an optional part, if instruction appears,
change the setting accordingly.
EXTERNAL CONTROLLER INPUT
Normally, you do not need to change this setting.
When using an optional part, if instruction appears,
change the setting accordingly.
SIGNAL RESPONSE LEVEL
Normally, you do not need to change this setting. Use
this option to set the level of response to signal changes.
3. Press the RETURN button to return to the normal
screen.
TIPS
• When both abnormal temperature and hardware error are
detected, the hardware error notification overrides.
• If TEMPERATURE ALERT or STATUS ALERT is set to
OSD & LED, alert messages will appear even if the OSD
DISPLAY is set to ON 2 or OFF.
• If TEMPERATURE ALERT or STATUS ALERT is set to
LED or OSD & LED, the power LED lights even if the LED
function is set to OFF.