E-12
Frequency of maintenance cycle will depend on the hardness or the impurities of the water that
you use; the harder the water the more often descaling will be necessary.
Pay attention not to spill water when cleaning the
fi
lter.
1
Remove the Water Tank and
Humidifying Tray.
(See E-11)
2
Remove the Humidifying Filter
from the Humidifying Tray.
Avoid spilling water from the Humidifying
Tray.
3
Preparing the descaling solu-
tion.
Citric acid, available at some drugstores,
or 100 % bottled lemon juice are used for
descaling. Choose either one to use, and
prepare the descaling solution.
<For using citric acid>
Dissolve 3 teaspoons of citric acid and 2
1/2 cups of lukewarm water in a suitable
container, and stir well.
<For using lemon juice>
100 % bottled lemon juice can be used
for descaling. Use only 100 % bottled
lemon juice with no pulp (strain juice if
necessary). Combine 1/4 cup lemon juice
and 3 cups of lukewarm water in a con-
tainer large enough to hold the Humidify-
ing Filter and stir well.
4
When using lemon juice, it is recommend-
ed to pre-soak longer than citric acid.
5
Rinse the Humidifying Filter re-
peatedly with lukewarm water
to remove all the solution resi-
due.
Inadequate rinsing may cause odour and
affect the performance and/or appear-
ance of the unit.
* Do not scrub the Hu-
midifying Filter, rinse
gently under lukewarm
water only.
6
Attach the Humidifying Filter
to the Humidifying Tray, and
replace the Humidifying Tray in
the unit.
• T h e H u m i d i f y i n g F i l t e r d o s e n o t
need to be oriented in any particular
position(forward/backward, up/down)
7
Plug in the unit, turn power
ON, and press the Filter Reset
Button on the display for more
than 3 seconds to reset.
HUMIDIFYING FILTER
Care Cycle
Once a month or when the Filter Indicator Light is on.
Pre-soak the Humidifying Filter
in the solution for 30 minutes
before cleaning.
CARE AND MAINTENANCE
You may notice reddish-brown or
white deposits forming on the surface
of the Humidifying Filter. These impu-
rities (calcium, etc.) are due to the im-
purities contained in tap water; this is
not a defect. Replace the Humidifying
Filter when it is covered completely in
white deposits.
•When not using
the unit for a long
periods of time,
dry the Humidify-
ing Filter com-
p l e t e l y b e f o r e
replacing.
When cleaning the unit, be sure to
fi
rst unplug the power cord, and never handle the plug with
wet hands. Electrical shock and/or bodily injury may occur as a result.
KC-930EU̲eng.indd 14
KC-930EU̲eng.indd 14
2009/09/11 11:11:02
2009/09/11 11:11:02
Summary of Contents for Plasmacluster KC-930EU
Page 19: ...ENGLISH Memo ...
Page 37: ...DEUTSCH Memo ...
Page 55: ...FRANÇAIS Memo ...
Page 73: ...NEDERLANDS Memo ...
Page 91: ...РУССКИЙ Памятка ...
Page 109: ...ČESKY Poznámky ...
Page 127: ...SLOVENSKY Poznámky ...
Page 145: ...MAGYAR Jegyzet ...
Page 163: ...УКРАЇНСЬКА Meмo ...
Page 180: ...Memo ...
Page 181: ...日本語 ...
Page 182: ... ﻣﺬﻛﺮﺓ ...
Page 183: ......