Appendix
-73
AC socket
POWER button
buttons
ENTER button
User service screw
4
Remove the lamp unit.
•
Loosen the securing screws from the
lamp unit. Hold the lamp unit by the
handle and pull it in the direction of
the arrow.
5
Insert the new lamp unit.
•
Press the lamp unit firmly into the lamp
unit compartment. Fasten the secur-
ing screws.
6
Attach the lamp unit cover.
•
Slide the lamp unit cover in the direc-
tion of the arrow. Then tighten the user
service screw.
Info
•
If the lamp unit and lamp cover are not cor-
rectly installed, the power will not turn on, even
if the power cord is connected to the projector.
Resetting the Lamp
Timer
Reset the lamp timer after replacing the lamp.
1
Connect the power cord.
•
Plug the power cord into the AC socket
of the projector.
2
Reset the lamp timer.
•
While pressing simultaneously
,
, and
on the projec-
tor, press
on the projector.
•
“LAMP 0000H” is displayed, indicating
that the lamp timer is reset.
Info
•
Make sure to reset the lamp timer only
when replacing the lamp. Otherwise, this
may cause the lamp to become damaged
or explode.
Securing
screw
Summary of Contents for PG-M20S - Notevision SVGA DLP Projector
Page 19: ...Setup and Connections Setup and Connections ...
Page 31: ...Basic Operation Basic Operation ...
Page 49: ...Easy to Use Functions Easy to Use Functions ...
Page 71: ...Appendix Appendix ...
Page 87: ...SHARP CORPORATION ...