MX-M350/M450 N/U SIMULATION 9 - 64
Operation/Procedure
(Automatic adjustment)
1) Select 1 or 2 with 10-key.
2) Press [START] key.
(Manual feed adjustment)
1) Enter the adjustment value with 10key.
2) Press [START] key.
When an adjustment error occurs, the trouble code (E7-17) is dis-
played simultaneously with “COMPLETED.”
Operation/Procedure
This simulation is used to change and check the engine soft SW.
Set this setting to the default.
There is no need to change this setting in the market.
Operation/Procedure
This simulation is used to change and check the scanner soft SW.
Set this setting to the default.
There is no need to change this setting in the market.
53-8
Purpose
Adjustment
Function
(Purpose)
Used to adjust the document scan start position.
(Used to adjust the scanner scan position in the
SPF mode front scan.)
Item
Set
range
Default
1
AUTO
Automatic adjustment
–
–
2
MANUAL
Manual feed adjustment
(Direct entry of a number)
1 - 70
(1 count:
0.1mm)
32
SIMULATION 53-8
SPF SCANNING POSITION ADJUSTMENT. PRESS START.
1.AUTO
2.MANUAL.
32
SIMULATION 53-8
SPF SCANNING POSITION ADJUSTMENT EXECUTING....
1. AUTO
SIMULATION 53-8
SPF SCANNING POSITION ADJUSTMENT COMPLETED.
1. AUTO
Select 1, and
press [START] key.
Normal completion
Trouble occurrence
Press
[SYSTEM SETTINGS] key.
Press [START] key, or
press [SYSTEM SETTINGS] key.
<Normal completion>
<Trouble occurrence>
1
1
1
SIMULATION 53-8
TROUBLE !! (E7-17)
SPF SCANNING POSITION ADJUSTMENT COMPLETED.
1. AUTO
32
SIMULATION 53-8
SPF SCANNING POSITION ADJUSTMENT. INPUT VALUE 1-70, AND
PRESS START.
2. MANUAL
Select 2, and
press [START] key.
55
55-1
Purpose
Setting
Function
(Purpose)
Used to set the specifications of the engine control
operations. (PCU PWB)
Section
Item
Operation Specifications
Press [START] key.
Press [SYSTEM SETTINGS] key or [START] key.
55-2
Purpose
Setting
Function
(Purpose)
Used to set the specifications of the scanner
control operations. (Scanner control PWB)
Section
Item
Operation Specifications
Press [START] key.
Press [SYSTEM SETTINGS] key or [START] key.
1
SIMULATION 55-1
ENGINNE SOFT SW. SETTING. SELECT 1-16, AND PRESS START.
1 2 3 4 5 6 7 8
0 0 0 0 1 0 0 1
SIMULATION 55-1
ENGINNE SOFT SW. SETTING. INPUT DATA No(1-8), AND PRESS
START.
SOFT SW-1:
1
SIMULATION 55-2
SCANNER SOFT SW. SETTING. SELECT 1-16, AND PRESS START.
1 2 3 4 5 6 7 8
0 0 0 0 1 0 0 1
SIMULATION 55-2
SCANNER SOFT SW. SETTING. INPUT DATA No(1-8), AND PRESS
START.
SOFT SW-1:
Summary of Contents for MX-M350