MAINTENANCE
SHARP
14
Maintenance Indications:
DK
Black Drum (Counter) has reached
the specified life.
Replace Black Drum
Process
Section
(Drum)
DC
Cyan Drum (Counter) has reached
the specified life.
Replace Cyan Drum
DM
Magenta Drum (Counter) has reached
the specified life.
Replace Magenta Drum.
DY
Yellow Drum (Counter) has reached
the specified life.
Replace Yellow Drum.
VK
Black Developer (Counter) has reached
the specified life.
Replace Black Developer.
Process
Section
(Developer)
VC
Cyan Developer (Counter) has reached
the specified life.
Replace Colour
Developer Kit.
VM
Magenta Developer (Counter) has reached
the specified life.
VY
Yellow Developer (Counter) has reached
the specified life.
FK1
Fusing Belt Print Counter has reached the
specified limit.
Replace the Fusing
Belt Kit.
Fuser
Section
FK2
Fuser Pressure Roller Print Counter has
reached the specified limit.
Replace the Pressure
Roller Kit.
FK3
Fuser Web Cleaner (Counter) has reached
the specified limit
(Pop Up FK3 Error – Web End Detected)
Replace the
Web Cleaning Kit
TK1
Primary Transfer Unit Counter has reached
the specified limit.
Replace Primary Transfer
Belt and Blade kits.
Transfer
Section
TK2
Secondary Transfer Unit Counter has
reached the specified limit.
Replace the Secondary
Transfer Belt Kit.
TA
Maintenance [All] Counter has reached specified limit
CA
Maintenance [Colour] Counter has reached specified limit
AA
Maintenance [All] & [Colour] Counters have reached the specified limits
Starting Powder:
The following starting powder should be applied to the relevant consumable item during maintenance:-
Starting Powder
OPC Drum
Primary Transfer Belt
MX-2640N
MX-3140N
MX-3640N
UKOG-0312FCZZ
[Stearic Acid]
CKOG-0345DS51
[Yellow Toner]
Note:
The Yellow Toner used for Start Powder (Primary Transfer Belt only) is the same as MX-31GTYA.
CAUTION:
Do not apply Stearic Acid (UKOG-0312FCZZ), Strontium Titanium (UKOG-0316FCZZ) or Titanium
Hydroxide (UKOG-0322FCZZ) starting powder to the Primary Transfer Belt.