MX-3610N SIMULATION 5 – 19
8-2
Purpose
Operation test/check/adjustment
Function (Purpose)
Used to check and adjust the operation of
the main charger grid voltage in each
printer mode and the control circuit.
* When the middle speed is adjusted, the
low speed are also adjusted simulta-
neously.
Section
Process (Charging)
Operation/Procedure
1) Select a speed with [MIDDLE] and [LOW] keys on the touch
panel.
2) Select a target item to be adjusted with scroll keys.
3) Enter the adjustment value with 10-key. (The value specified
on the label of the high voltage PWB must be entered.)
* When the key is pressed, the setting value of each
item can be changed with 1up (1down) collectively.
4) Press [EXECUTE] key.
The set value is saved and the voltage entered with step 3) is
output for 30 sec.
When [EXECUTE] key is pressed, the output is terminated.
8-6
Purpose
Operation test/check/adjustment
Function (Purpose)
Used to check and adjust the operation of
the transport voltage and the control circuit.
Section
Process (Transport)
Operation/Procedure
1) Select a target item to be adjusted with scroll keys.
2) Enter the set value with 10-key.
Enter the default value specified on the following list.
3) Press [EXECUTE] key.
The set value is saved and the voltage corresponding to the
set value is output for 30 sec.
When [EXECUTE] key is pressed, the output is terminated.
Item/Display (Mode)
Content
Adjustment
range
Actual voltage
18cpm/
20cpm/
23cpm
machine
26cpm/
31cpm
machine
36cpm
machine
MIDDLE
A
MIDDLE SPEED GB_K
Main charger grid voltage (Middle speed mode)
K
150 - 850
–615V
5V
–620V
5V
–625V
5V
B
MIDDLE SPEED GB_C
Main charger grid voltage (Middle speed mode)
C
150 - 850
–615V
5V
–620V
5V
–625V
5V
C
MIDDLE SPEED GB_M
Main charger grid voltage (Middle speed mode)
M
150 - 850
–615V
5V
–620V
5V
–625V
5V
D
MIDDLE SPEED GB_Y
Main charger grid voltage (Middle speed mode)
Y
150 - 850
–615V
5V
–620V
5V
–625V
5V
LOW
A
LOW SPEED GB_K
Main charger grid voltage (Low speed mode)
K
150 - 850
–610V
5V
–610V
5V
–610V
5V
B
LOW SPEED GB_C
Main charger grid voltage (Low speed mode)
C
150 - 850
–590V
5V
–590V
5V
–590V
5V
C
LOW SPEED GB_M
Main charger grid voltage (Low speed mode)
M
150 - 850
–590V
5V
–590V
5V
–590V
5V
D
LOW SPEED GB_Y
Main charger grid voltage (Low speed mode)
Y
150 - 850
–590V
5V
–590V
5V
–590V
5V