MD-X60H
– 20 –
1. Preparation for adjustment
Test disc
MD SECTION
Type
Test disc
Part No.
1
High reflection disc TGYS1 (SONY) [for Playback]
RRCDT0101AFZZ
2
Low reflection disc
Recording minidisc
UDSKM0001AFZZ
3
Head Adjusting transparent
RRCDT0103AFZZ
[TEAC Test MD]
4
Low reflection disc
Pre-adjustment disc
88GMMD-318
Extension Cable (See Fig. 19)
Type
Part No.
1
Extension PWB for servicing
RUNTK0457AFZZ
2
Extension Connector (2 Pin)
QCNWK0059AFZZ
3
Extension Connector (6 Pin)
QCNWK0107AFZZ
4
Extension Cable (5 Pin)
QCNWK0109AFZZ
5
Extension Cable (28 Pin)
QCNWK0108AFZZ
When the combination of mechanism/pickup and PWB was changed , set the TEST mode to perform the AUTO preliminary
adjustment and AUTO adjustment, write the adjustment data in EEPROM.
When EEPROM was replaced, set the TEST mode,write the EEPROM set data (p29,p30) and then perform the preliminary
adjustment and AUTO adjustment, write adjustment data in EEPROM.
Figure 20 Conection of Extention Cable
5Pin extension flat cable
QCNWK0109AFZZ
2Pin extension connector
QCNWK0059AFZZ
CN1601(Bottom side)
CN1602
CN1252
CN1603
CN1604(Bottom side)
CN1101
MD MAIN PWB
6P-2P extension connector
QCNWK0107AFZZ
28Pin extension
flat cable
QCNWK0108AFZZ
Extension PWB for service
(RUNTK0457AFZZ)
Fit the extension PWB for service to the mechanism
From Optical
Pickup Unit
From Magnetic Head
From
motor
From mecha-
nism switch
PWB