![Sharp LS013B7DH07 Technical Literature Download Page 14](http://html.mh-extra.com/html/sharp/ls013b7dh07/ls013b7dh07_technical-literature_367301014.webp)
SPEC No.
LD-28204A
MODEL No.
LS013B7DH07
PAGE
12
5. Absolute Maximum Rating
Table5-1
Absolute Maximum Rating ( VSS=0V , VSSA
=
0V )
Item
Symbol
MIN.
MAX.
Unit
Remark
Power
supply
voltage
Analog
VDDA
-0.3
+3.6
V
Logic
VDD
-0.3
+3.6
V
[Note 5-1]
Input signal voltage(high)
VDD
V
[Note 5-2]
Input signal voltage(low)
-0.3
V
Strage Temperature
Tstg
-30
+80
℃
[Note 5-3,4]
Operation Temperature
(at panel surface)
Topr
-20
+70
℃
[Note 5-4,5]
[Note 5-1] Applies to EXTMODE.
[Note 5-2] Applies to SCLK, SI, SCS, DISP, EXTCOMIN.
[Note 5-3] Do not exceed this temperature in any parts of module.
[Note 5-4] Humidity 95%RH Max.(Ta
≦
40
℃
)
Attention should be paid to static electricity
Maximum wet bulb temperature is 39
℃
or lower. No condensation is allowed.
Cndensation will cause electeical leak and may cause the module to not meet this specification.
[Note 5-5] Operating temperature is the temperature that guarantees only for the operation.
For contrast, response time, and other display quality determination, use Ta
=+
25
℃
.
SHARP Confidential
technical
literature
©Copyright 2016 SHARP All rights reserved
©Copyright 2016 SHARP All rights reserved
Summary of Contents for LS013B7DH07