5. Absolute Maximum Rating
Table5-1
( GND
=
0V )
Item Symbol
MIN.
MAX.
Unit
Remark
Analog VDDA
-0.3
+5.8
V
Power
supply
voltage
Logic VDD
-0.3
+5.8
V
[Remark5-1]
Input signal voltage(high)
VDD
V
[Remark5-2]
Input signal voltage(low)
-0.3
V
Strage Temperature
Tstg
-30
+80
℃
[Remark5-3,4]
Operation Temperature
(at panel surface)
Topr1 -20 +70
℃
[Remark5-5]
[Remark5-1] Applies to EXTMODE.
[Remark5-2] Applies to SCLK, SI, SCS, DISP, EXTCOMIN.
[Remark5-3] Do not exceed this temperature in any parts of module.
[Remark5-4] Maximum wet bulb temperature is 57
℃
or lower. No condensation is allowed.
Cndensation will cause electeical leak and may cause the module to not meet this specification.
[Remark5-5] Operating temperature is the temperature that guarantees only for the operation.
For contrast, response time, and other display quality determination, use Ta
=+
25
℃
.