SPEC No.
LCP-2110019B
MODEL No.
LS013B7DH01
PAGE
3
z
Equipment and containers
Process equipment such as conveyer, soldering iron, working bench and containers may possibly generate
electrostatic charge up and discharge. Equipment must be grounded through 100Mohms resistance. Use
ion blower.
z
Floor
Floor plays an important role in leaking static electricity generated in human body or equipment. If the floor
is made of insulated material (such as polymer or rubber material), such static electricity may charge.
Proper measure should be taken to avoid static electricity charge (electrostatic earth: 100Mohms).There is
a possibility that the static electricity is charged to them without leakage in case of insulating floor, so the
electrostatic earth:1×10
8
Ω
should be made.
z
Humidity
Humidity in work area relates to surface resistance of the persons or objects that generate
electrostatics, and it can be manipulated to prevent electrostatic charge. Humidity of 40% or
lower increases electrostatic earth resistance and promotes electrostatic charging. Therefore,
the humidity in the work area should be kept above 40%. Specifically for film peeling process
or processes that require human hands, humidity should be kept above 50% and use electricity
removal blower.
z
Transportation/Storage
Containers and styroform used in transporation and storage may charge electrostatic (from friction and
peeling) or electrostatic charge from human body, etc. may cause containers and styroform to have induced
charge. Proper electrostatic measure should be taken for containers and storage material.