LC-52XS1E/RU/LC-65XS1E/RU
3 – 20
* The OSD display is an example.
If another ODS is previously displayed, the status is reset (MENU or similar).
2. Volume Maximum Level [MAXIMUM VOLUME]
3. Volume Fixed [VOLUME FIXED]
4. Volume Fixed Level [VOLUME FIXED LEVEL]
No Power off by power button. No Power off by remote control.
5. R/C Operation [RC BUTTON]
6. Main Unit Operation [PANEL BUTTON]
Selection
0~60 (Loop is not provided.)
Default
60
Function
• Even if VOL is adjusted to a value higher than the adjusted one, it is not set to that value. (Only the speakers of
(Only the speakers of the main unit)
Exception
Remarks
• When it is set to 59 or less, the number is displayed and the volume bar is not displayed during operation in the ordi-
nary mode.
• VOLUME can be abbreviated to VOL.
Selection
“VARIABLE” or “FIXED” is selectable. (Loop is provided.)
Default
“VARIABLE”
Function
It is selectable whether or not the volume is fixed to the value adjusted in the volume fixed level mode.
(Only the speakers of the main unit)
Exception
• In the adjustment process, the volume can be set as desired regardless of this setting.
Keys disabled when not
set to Default
• Volume high/low (VOL+/-) (Both R/C and main unit)
• Mute (MUTE)
Remarks
• Volume Fixed is prior to Volume Maximum Level.
• Even if the above disabled keys are operated, the volume is not displayed.
• VOLUME can be abbreviated to VOL.
Selection
0~60 (Loop is not provided.)
Default
Currently set volume
Function
The volume is fixed to the adjusted value. (Only the speakers of the main unit)
Exception
• In the adjustment process, the volume can be set as desired regardless of this setting.
Keys disabled when not
set to Default
Remarks
• When Volume Fixed is set to “VARIABLE”, the setting is inhibited to change.
• VOLUME can be abbreviated to VOL.
Selection
Default
Function
“RESPOND” or “NO RESPOND” is selectable. (Loop is provided.)
RESPOND
R/C key operation is set.
When set to “NO RESPOND”, the R/C keys are disabled in the ordinary mode.
The power key (Power ON/Standby Key) is also disabled.
Exception
• Regardless of the setting contents, the process mode, inspection mode and PUBLIC_Mode Key are enabled.
• Regardless of the setting contents, all keys can be used while entering the process mode, inspection mode or
PUBLIC_Mode.
Remarks
The CARD function stops all functions including the input switching and direct key when set to “NO RESPOND”.
Selection
Default
Function
Exception
“RESPOND” or “NO RESPOND” is selectable. (Loop is provided.)
RESPOND
NO RESPOND: Excluding power supply (Video/Standby key), the main unit keys are disabled.
• Regardless of the setting contents, the start operation of the process mode, inspection mode and PUBLIC_Mode is
enabled.
• Regardless of the setting contents, all keys can be used while entering the process mode, inspection mode and
PUBLIC_Mode.
When power button on the main unit is pressed
When power button on R/C is pressed
No Power off by remote control.
No Power off by power button.