LC-52XS1E/RU/LC-65XS1E/RU
3 – 13
4. Software version
[5] Special features
1. NORMAL STANDBY CAUSE (Page 1/46)
Display of a cause (code) of the last standby.
The cause of the last standby is recorded in EEPROM whenever possible.
Checking this code will be useful in finding a problem when you repair the troubled set.
2. EEP SAVE (Page 46/46)
Storage of EEP adjustment value
3. EEP RECOVER (Page 46/46)
Retrieval of EEP adjustment value from storage area.
[6] Functional explanation of AQUOS STANDBY CAUSE
[Method of display]
• It is displayed in the top page of the process mode (The page displayed first when entering the process mode: 1/46).
(Refer to the following display example.)
[Content of display]
1.
NORMAL STANDBY CAUSE
• The reason that became a power-off by using usually or using the main unit is displayed. (Only the one latest)
It is not displayed when power supply OFF is carried out with remote control.
2.
ERROR STANDBY CAUSE
• When main CPU becomes a power-off detecting some abnormalities, the reason and the using time of the set by the point
that became a power-off is displayed 5 times.
• In addition, when time information is acquirable from digital broadcasting, the date and time of error generating is recorded and displayed
simultaneously, and when time information cannot be acquired, it becomes the above-mentioned display.
"0" is displayed when abnormalities are not detected once.
A display is clearable by operation of remote control.
* Display will be cleared, if "STANDBY CAUSE RESET" is chosen on page 46/46, "ON" is set up with the voice button (+/-) of remote control and
the "OK." key is pressed.
3.
MONITOR ERR STANDBY
The abnormal detection part is displayed by the blinking frequency of power LED and OPC LED when turning it off detecting abnormality on the
monitor side at an abnormal temperature etc. of the monitor.
Moreover, the latest, abnormal content detected with the monitor microcomputer can be displayed four times memory and MONITOR SUB ERR
STANDBY as an error code.
(1) Monitor Main micon Software
Ver. 1.0 *1
(2) Monitor Sub micon Software
Ver. 1.0 *1
*1 Please refer to the change report document for the latest version (Issued it to SEES).