20
KB-6025MS
KB-6025MK
KB-6025MW
- 3
AN5- AN3
IN
Terminal to change cooking input according to the Model.
By using A/D converter contained in the LSI, DC voltage in accordance with the Model
in operation is applied to set up its cooking constant.
4
AN2
IN
Input signal which inform the drawer door is in the middle position between the opened
position and the closed position, to LSI from the door position switch rear.
5
AN
IN
Terminal not used.
6
AN0
IN
Terminal not used.
7
CNVSS
IN
Power source voltage: 0V (GND).
VC voltage of power source circuit input. Connected GND.
8
RESET
IN
Auto clear terminal.
Signal is input to reset the LSI to the initial state when power is applied. Temporarily set
to “L” level the moment power is applied, at this time the LSI is reset. Thereafter set at
“H” level.
9
P62
OUT
Terminal not used.
0
P6
IN/OUT Terminal not used.
VSS
IN
Power source voltage: 0V (GND).
VS voltage of power source circuit input. Connected GND.
2
XIN
IN
Internal clock oscillation frequency setting input.
The internal clock frequency is set by inserting the ceramic filter oscillation circuit with
respect to Xout terminal.
3
XOUT
OUT
Internal clock oscillation frequency control output.
Output to control oscillation input of Xin.
4
VCC
IN
Power source voltage: +5V.
VC voltage of power source circuit input.
5
P60
IN
Plus signal coming from the Microwave drawer door open-close motor is input into P60
as revolution number.
6
P37
IN
Input signal which communicates the drawer door open information to LSI from
the door position switch front.
Door opened; “L” level signal(0V).
Door closed; “H” level 5V).
7
P36
OUT
Signal to change the rotational direction is output to the Microwave drawer door
open-close motor.
8
TXOUT
OUT
Signal to change the rotational speed is output to the Microwave drawer door open-close
motor.
9
P34
OUT
Power source to drive the Microwave drawer door open-close motor is output.
20
RXD2
IN
Input terminal to check the data of display.
Data signal from IC-2 is input to RXD2 to check the flow of the data.
2
TXD2
IN
Output terminal to send IC-2 the data.
The data of display is output to IC-2.
22
SCLK2
OUT
Clock timing signaI output terminal.
Clock timing signal is sent to IC-2.
23
P30
OUT
Signal to reset LSI.
Signal is output to reset IC-2.
24 - 25
COM3 - COM2
OUT
Terminal not used.
26
COM
OUT
Common data signal.
Connected to LCD signal C5.
DESCRIPTION OF LSI (IC-1)
The I/O signal of the LSIis detailed in the following table.
Pin No.
Signal
I/O
Description