13
·
7
13
• Set the addresses 000600 to 000777
(8)
when the master station PC is JW model and uses a special I/O
module for slave station.
• Initial value of the address 000400 to 000407
(8)
are all FF
(H)
. Initial value of 000600 to 000777
(8)
are all
00
(H)
.
(5/6)
(same as 000600 to 000603) (No. 3)
(same as 000600 to 000603) (No. 4)
(same as 000600 to 000603) (No. 5)
(same as 000600 to 000603) (No. 6)
(same as 000600 to 000603) (No. 7)
(same as 000600 to 000603) (No. 8)
(same as 000600 to 000603) (No. 9)
(same as 000600 to 000603) (No.10)
(same as 000600 to 000603) (No.11)
(same as 000600 to 000603) (No.12)
(same as 000600 to 000603) (No.13)
(same as 000600 to 000603) (No.14)
(same as 000600 to 000603) (No.15)
(same as 000600 to 000603) (No.16)
(same as 000600 to 000603) (No.17)
(same as 000600 to 000603) (No.19)
(same as 000600 to 000603) (No.20)
(same as 000600 to 000603) (No.21)
(same as 000600 to 000603) (No.22)
(same as 000600 to 000603) (No.23)
(same as 000600 to 000603) (No.24)
(same as 000600 to 000603) (No.25)
(same as 000600 to 000603) (No.26)
(same as 000600 to 000603) (No.27)
(same as 000600 to 000603) (No.28)
(same as 000600 to 000603) (No.29)
(same as 000600 to 000603) (No.30)
(same as 000600 to 000603) (No.31)
(same as 000600 to 000603) (No.32)
000400
to
000407
Address
(8)
Set contents
Setting method (value, example)
Slave station I/O type
• Use 0 (OFF, for ZW
models) or 1 (ON,
for JW models) in
the corresponding
bits for each station
number listed on
the right.
○
○
−
−
Fix
JW-PC
ZW-PC
000600
to
000603
Data register
address of special
I/O module (No. 1)
• When the slave station 01 to 04
(8)
I/Os are ZW models and slave station
05 to 77
(8)
I/Os are JW models.
(Address)
(Bit pattern)
000400
−
11100000
000401
−
11111111
to
to
000407
−
11111111
Slave station number (00 to 77
(8)
)
Upper 4 bits: rack number (0, 1)
Lower 4 bits: slot number (00 to 0F
(H)
)
Number of data bytes (01 to 64
(D)
)
Register top address (file address)
D7 bit: 1 (Set), 0 (Not set)
Fix
Manua
l
000600
000601
000602
000603
Bit address 7 6 5 4 3 2 1 0
000400
07 06 05 04 03 02 01
−
000401
17 16 15 14 13 12 11 10
000402
27 26 25 24 23 22 21 20
000403
37 36 35 34 33 32 31 30
000404
47 46 45 44 43 42 41 40
000405
57 56 55 54 53 52 51 50
000406
67 66 65 64 63 62 61 60
000407
77 76 75 74 73 72 71 70
Manua
l
000704 to 000707
000710 to 000713
000714 to 000717
000720 to 000723
000724 to 000727
000730 to 000733
000734 to 000737
000740 to 000743
000744 to 000747
000750 to 000753
000754 to 000757
000760 to 000763
000764 to 000767
000770 to 000773
000774 to 000777
Address
(8)
Set contents
Data register address of special I/O (No.18)
(same as 000600 to 000603)
Address
(8)
000604 to 000607
000610 to 000613
000614 to 000617
000620 to 000623
000624 to 000627
000630 to 000633
000634 to 000637
000640 to 000643
000644 to 000647
000650 to 000653
000654 to 000657
000660 to 000663
000664 to 000667
000670 to 000673
000674 to 000677
000700 to 000703
Set contents
Data register address of special I/O (No. 2)
(same as 000600 to 000603)