• Set “01
(H)
(=001
(8)
)” in parameter address 004002
(8)
and change to “relay/register link.”
(Operation example of JW-13PG)
Lower
Upper
00
(H)
·
In case of standard function, set top address by file address
(8)
.
In case of save memory function, set number of offset bytes.
004004
(8)
004005
(8)
004006
(8)
004007
(8)
Lower
Upper
00
(H)
·
00
(H)
: The top address is the same address of the master station
regardless of the value set at of 004004 to 004005
(8)
.
• Set the number of connecting stations (02 to 64
(D)
) including the master station in the parameter
address 004003
(8)
by octal.
• If you try to set values other than 02 to 64
(D)
, JW-20CM the displays 6F
(H)
error code.
From the previous page
Data link function setting [HEX (hexadecimal), byte]
Set number of connecting stations [DCM (decimal), byte]
Screen display of JW-13PG
Screen display of JW-13PG
Set top address of relay link area on slave station (01 to 77) (at standard function)/number of
offset bytes (memory capacity save function)
Slave
station
01
80
(H)
: The top address is different from the address of the master
station (Offset is valid).
For the save memory function, set in 80
(H)
.
004374
(8)
004375
(8)
004376
(8)
004377
(8)
00
(H)
Slave
station
77
(8)
80
(H)
To the next page
• In case of setting
コ
0200 (file address 000200
(8)
) in parameter addresses 004004 to 004007
(8)
(slave station 01) and set 4 (number of off set bytes) in 004010
(8)
to 004013
(8)
(slave station 02).
(Example for page 11·10.)
〜
• Set in parameter addresses 004004 to 004377
(8)
. These top addresses should not overlap the
register link area, flag area, or any area used by other option module.
04000 HEX 880
04001 HEX 00F
I PARAM.
>04002 HEX 01
04001 DCM 000
04002 DCM 001
I PARAM.
>04003 DCM 003
File address: OCT (octal), word
File number/flag: HEX (hexadecimal), byte
Set the "same" as or "different" from the
master station: HEX (hexadecimal) , bytes.
After converting into decimal
notation in 004003
(8)
, write “003.”
Write 001
(8)
to 004002
(8)