Pull up and remove 
the tank.

Pull up and remove 
the  humidification
filter set.

Tray

Humidification filter 
set

Pull out the tray.

CLEANING AND STORAGE

NOTE

1

2

Warning

• Always remove the power plug from the wall outlet when cleaning.

Electrical shock or bodily injury may occur as a result.

• Do not use chlorine bleach and acidic cleaners to clean the unit interior. Harmful gases may

be generated from the cleaner as a result.

• Do not clean while the unit is in operation or immediately after use.

Electrical shock or bodily injury may occur as a result.

When the maintenance lamp lights

When the total humidification time reaches approximately 80 hours, long beeps will be heard for about 10
seconds and the maintenance lamp will light to notify that the unit has not been cleaned for some time.

Clean the unit by following cleaning procedure .

Insert the power plug into the wall outlet and press the
Power ON/OFF button.

Press and hold the Reset button until a short beep is
heard (about 3 seconds).

(To reset the Maintenance lamp.)

• Degree of soiling will differ depending on the water quality. Clean frequently even if cleaning was per-

formed within the last 2 weeks.

• Internal temperature will rise and the amount of humidification will decrease when brownish red and

white impurities accumulate within the humidifier filter, tray and tank or when there is accumulation of
dust on the air filter. Clean the unit frequently regardless of whether the maintenance lamp turns on to
avoid malfunction of the unit.

• After cleaning, be sure to press and hold the Reset button until a short beep is heard (about 3 seconds).
• Since there is the possibility of water spilling when cleaning the unit, move the unit to a location where

water may be spilled.

Cleaning procedure

Remove the power plug, and remove all
parts.

E m p t y   t h e
water within
the tray.

Clean each part, and reattach
each part.

Insert the power plug into the
wall outlet and press the
power ON/OFF button.

CAUTION

• Reattach each part to their original state.
• The tank must be removed first in order to

remove the tray.

Pull out the tray slowly to avoid water spills.

(Page 16)

3

Maintenance 
lamp

Reset button

Beep

Press and hold the reset but-
ton about 3 seconds until a
short beep is heard  (To reset
the maintenance lamp).

5

Tray

Summary of Contents for HV-50CXE

Page 1: ...ion Type Humidifier OPERATION MANUAL CONTENTS Safety precautions 2 Effect of Cluster Ions 4 How the Hybrid Humidifier Works 4 Things to Keep in Mind 5 Cautions concerning Usage 6 Names and Operations of Parts 7 Operation panel 8 Correct Usage 10 1 Preparation 10 2 Operation 11 3 Stopping operation 12 About humidity setting mode throat moisturizing mode si lent mode continuous operation mode About ...

Page 2: ...ctrical shock and or malfunction may occur causing bodily injury as a result Do not use chlorine bleach acidic cleaners Harmful gas may be generated from the cleaner causing a health hazard Do not use electrical current other than 220 240V Fire electrical shock and or malfunction may occur as a result Do not modify Disassembly repair to be performed only by authorized techni cian Fire electrical s...

Page 3: ...result Replace the tank water daily with fresh tap water Keep the unit interior free of soiling by cleaning periodically Using the unit without periodical cleaning will result in the emission of foul odors caused by propaga tion of molds and bacteria from soiling and water scaling Occasionally your body may react sensi tively to such odors depending on your constitution and may be hazardous to you...

Page 4: ...WORKS Hybrid humidifier uses a combination of evaporation method which humidifies the air by applying air to the humidification fil ter and the heat method which assists evaporation by warming the air using a heater When starting operation warm air is applied to the humidification filter for humidification The heater is turned off when the air reaches the set filter and uses the air in the room to...

Page 5: ...operation the sen sors will be influenced by the internal tempera ture and humidity and requires about 5 minutes for the current humidity display to stabilize Steam and mist are not visible Since the unit uses the humidification method of applying air to the humidification filter and dis charging humidified air heat evaporation steam will not be visible as with steam fan type and ul trasonic type ...

Page 6: ...ns of temperature and hu midity sensors and safety mechanisms may occur as a result In addition the air within the tank may expand causing the water to spill Take caution to freezing water If there is a risk of water becoming fro zen empty the wa ter within the tank and tray Using fro zen water may cause malfunction to occur as a result Clean periodically Adhering of large amounts of water scaling...

Page 7: ...Handle Power cord Power Plug Tray Temperature humidity sensors Unit interior Unit bottom Do not hold this section when carrying as it will become deta ched Dirt and the smell of water are restrained with the sheet containing the zeolite and activated carbon set to the humidification filter Humidification filter set Humidification filter zeolite sheet Zeolite sheet Humidification filter set interio...

Page 8: ...ration mode Humidity setting Green Set humidity guide About 60 About 50 About 40 Auto humidification Green Performs auto humidification operation Silent Yellow Performs continuous silent operation Continuous Red Performs continuous operation using maximum humidifying capacity During Silent and Continuous operations the unit will stop when the humidity of the intake port reaches 80 or higher To pre...

Page 9: ...es the remaining time of operation Maintenance lamp yellow Indicates time for cleaning Indicates time for cleaning Unit operates for the set time and turns off auto matically Cluster ion operation is turned on and off Cluster ion operation can be performed independently The lamp lights during cluster ion operation Humidity Select button Operation mode is set ...

Page 10: ... see that there is no water leak Be sure to wipe off any excess water around the tank Set the tank into the unit Hook the groove on the tank to the tab on the unit The unit may not operate if the tank is set at an angle Align the mark on the tank and the mark on the unit Do not expose the unit to water Short circuit and or electrical shock may occur as a result Do not use hot water of 40 C or high...

Page 11: ...made with the tank empty Empty all water from the tray and tank Water remaining within the tank and tray will cause humidification Set the Cluster ion button to ON Cluster ion lamp and cluster ion sign lit Set the Humidity Select button to OFF 2 short beeps will be heard Operation display lamp off 40 50 60 Green Green Green Green Continuous Silent Auto humidification Yellow Red Humidity setting mo...

Page 12: ... blue does not light when pressing the Power ON OFF button and set ting the cluster ion operation to ON To return the setting to the original state repeat step 1 or remove the power plug and reinsert to cancel the setting When the tank is empty Series of long beeps will be heard for about 10 seconds and the water supply lamp will flash The current humidity lamp and cluster ion sign will turn off a...

Page 13: ...is displayed as a guide The humidity may differ depending on the area of the room The current humidity will not be displayed during cluster ion operation During continuous operation mode and silent mode the unit will stop operate once the hu midity in the room reaches 80 or higher Too much humidification may cause condensation on windows and within closets Auto humidification mode will humidify th...

Page 14: ...s pressed and the fan stops for about 1 minute rest Remove the tank and carry after disconnecting the power plug Remove the tank Not removing the tank may cause the water level within the tray to rise and spill Hold the handle unit bottom and carry slowly using both hands Tilting or shaking the unit may cause the water within the tray to spill The built in tip over safety mechanism may cause a cla...

Page 15: ... Degree of soiling will differ depending on the water quality Clean frequently even if cleaning was per formed within the last 2 weeks Internal temperature will rise and the amount of humidification will decrease when brownish red and white impurities accumulate within the humidifier filter tray and tank or when there is accumulation of dust on the air filter Clean the unit frequently regardless o...

Page 16: ...on filter set in the original state Insufficient rinsing will cause citric acid odors defor mation and discoloration of unit Citric acid is a type of food additive and is not harm ful to the human body However store in a location that is out of the reach of children Citric acid can be purchased at your local pharmacy or pharmaceutical store Replacement guide for humidification filter About 6 month...

Page 17: ... no remain ing detergent within the tank Unit Clean once about every month Wipe with soft cloth For stubborn dirt clean with a cloth damped with neutral detergent and wipe off using a well wrung cloth making sure there is no remaining detergent CAUTION To prevent deformation and dis coloration do not wipe with gaso line paint thinner benzene or al kaline detergent When using a chemical fiber cloth...

Page 18: ...om temperature higher than 0 C to avoid water within the unit from freezing Page5 Water Supply lamp flashes even when there is water in the tank Is the float caught The humidity does not rise Is the room larger than the applicable floor area Is the room being ventilated or is the floor carpeted Humidity may not rise effectively when ventilating when the walls and floor are dry and when the floor i...

Page 19: ... or small room Circulate the air within the room Page5 There are differences in the humidity depending on the areaof the room Accuracy and response speed to changes in humidity are different from the humidity sensor of the humidifier and other humidity instrumentation Use the humidity display only as a guide This is the sound that is produced when water is being supplied to the tray from the tank ...

Page 20: ...he fan stops to operate for some reason or when the humidification filter or air filter is continuously used without cleaning high temperature error is detected and opera tion is stopped When the temperature of the intake port becomes approximately 0 C operation is stopped for safety If the unit is tilted or tips over or if there is vibration opera tion is stopped TINSJA069TDRZ 03HK TH Printed in ...

Reviews: