EN-10
1.
Remove the unit cover,
and pull out the unit
holder.
2.
Remove dusts from the
electrode section.
3.
Insert the unit holder in
the Main Unit, and
install the unit cover.
CAUTION
• Do not clean with anything other than the unit cleaning brush. Doing so could lead to failures in the unit.
• A bent electrode could be cut off and dropped during the cleaning process, but it will not change the performance.
• Do not touch the electrode directly. Doing so could lead to pain/itching.
• Do not transform the electrode section. Doing so can damage it.
• Do not touch the connection terminals. Doing so can damage them.
NOTE
How to clean hard to remove dirt.
Back Panel
1. Add a small amount of neutral detergent
to water and soak for about 10 minutes.
CAUTION
Do not apply excessive pressure when
scrubbing the back panel.
2. Rinse off the neutral detergent with clean water.
3. Completely dry the
fi
lter in a wellventilated area.
Sensor Filter
1. Remove the Back Panel.
2. Remove the sensor
fi
lter.
3. If the sensor
fi
lter is very dirty, wash it
with water and dry it thoroughly.
Pla sm a clust e r I on Ge ne rat ing U nit
(e le c t rode se c t ion)
H EPA FI LT ER / DEODORI Z I N G FI LT ER
Wipe with a dry, soft cloth
Remove the dust gently with a cleaning
tool such as a vacuum cleaner.
M AI N U N I T / BACK PAN EL
CARE AN D M AI N T ENAN CE
Remove the dust on the fi lters.
CAUTION
Do not wash the
fi
lters. Do not expose to sunlight.
(Otherwise these
fi
lters may lose ef
fi
cacy.)
HEPA FILTER
Maintain only the tagged
surface. Do not clean up the
opposite surface.
The
fi
lter is fragile, so be
careful not to apply too
much pressure.
DEODORIZING FILTER
Both surfaces can be
maintained.
The
fi
lter may be broken if
being too much power is
applied on it, so please
handle it with care.
Some odors absorbed by the
fi
lters will break down over time, causing additional odors. Depending on usage conditions,
and especially if the Main Unit is used in environments signi
fi
cantly more severe than a normal household, these odors may
become noticeable sooner than expected.
Replace the
fi
lter in those cases or if dust is unable to be removed after maintenance.
Tag
Sensor
Filter
Unit Cleaning Brush
Electrode Around the base
Before cleaning
After
cleaning
Back Panel
(Pre Filter)