background image

ENGLISH

E-9

FILTER REPLACEMENT GUIDELINES

Do not wash and reuse the filter

The filter life and replacement period are based on the condition of smoking 5 cigarettes per 

day and the dust collection power is reduced by half compared with that of new filter. 

Filter life varies depending on the room environment, usage, and location of the unit.

We recommend to replace the filter more frequently if the product is used in a condition signif-

icantly severer than normal household use.

REPLACING THE FILTER

Replacement Filter

•  Please consult your dealer for purchase of replacement filter.

•  Use only filter designed for this product.

Disposal of Filter

 Please dispose of the replaced filter according to the local disposal laws and regulations.

See page E-5 for directions on how to 

install the filter when replacing.

Replacement timing

About 2 years after operating

Be sure to remove the power plug from the wall outlet.

Date Label

Model:FZ-F40SFE

• HEPA Filter : 1 unit

• Deodorizing Filter : 1 unit

HEPA Filter materials :
  •Filter : Polypropylene

  •Frame : Polyester

Deodorizing Filter materials :
  •Polypropylene, Polyester, Activated charcoal

OM_FP-F40E_40L_EN_MA_CS.indb   9

4/21/2558 BE   3:12 PM

Summary of Contents for FP-F40E

Page 1: ...indicates an approximate number of ions supplied into air of 1 cm3 which is measured around the center of a room with the high density plasmacluster 7000 applicable floor area at 1 2 m height above the floor at the medium wind volume in air purifying mode when an air purifier using the high density plasmacluster ion evolving device is placed close to a wall This product is equipped with a device c...

Page 2: ...d by the filters may break down over time resulting in additional odour Depending on the usage environment especially when the product is used in extreme environments significantly more severe than normal household use this odour may become strong in a shorter period than expected If the odour persists the filters should be replaced The air purifier is designed to remove air suspended dust and odo...

Page 3: ...ECIFICATIONS E 11 CONTENTS FEATURES Unique Combination of Air Treatment Technologies Triple Filtration System Plasmacluster TRAPS DUST Pre filter traps dust and other large airborne particles DECREASES ODOURS Deodorizing filter absorbs many common household odours REDUCES POLLEN MOLD HEPA filter traps 99 97 of particles as small as 0 3 microns FRESHENS Plasmacluster treats the air similar to the w...

Page 4: ...rp Approved Service Centre or similarly qualified person in order to avoid a hazard Do not operate when using aerosol insecticides or in rooms where there is oily residue incense sparks from lit cigarettes chemical fumes in the air or in very high humidity conditions such as a bathroom Be cautious when cleaning the unit Corrosive cleansers may damage the exterior Only a Sharp Authorized Service Ce...

Page 5: ... other items may come in contact with and restrict the air intake and or air outlet Avoid use in locations where the unit is exposed to condensation or drastic temperature changes Appropriate conditions are when room temperature is between 0 35 ºC Place on a stable surface with sufficient air circulation When placing the unit on a heavily carpeted area the unit may vibrate slightly Avoid locations...

Page 6: ...E Button HAZE indicator Light green 14 Back Panel Pre Filter 6 POWER ON OFF Button 15 Bottom Tabs 7 DUST SIGN 16 Power Cord 8 PLASMACLUSTER SIGN 17 Plug Shape of plug depends on country 9 Handle 18 Date Label FRONT BACK 16 13 14 PLASMACLUSTER SIGN blue Plasmacluster ON off Plasmacluster OFF 8 7 Clean Impure Red Orange Green 3 4 5 6 9 10 11 12 15 DUST SIGN Indicates the air purity of the room in 3 ...

Page 7: ...ilter within the main unit Do not install the filter backwards or the unit will not operate properly Upper Tabs Do not operate the unit without the filter Date Label Pull Push Push Be sure to remove the power plug from the wall outlet 4 Replace the Back Panel to the main unit 5 Fill in the usage start date on the Date Label Use the date as a guide for the filter re placement schedule Bottom Tabs H...

Page 8: ...Ion will not be released It is possible to switch this mode to another while operating However the HAZE mode will not function after switching mode NOTE FAN SPEED SLEEP The unit will operate very quietly and the fan speed is automatically switched depending on the amount of impurities in the air DUST PLASMACLUSTER SIGN go off automatically Even though the indicator is off Plasmacluster Ion is disp...

Page 9: ...DUST SIGN is constantly red to reduce sensitivity and set to High if the DUST SIGN is constantly green to increase sensitivity OFF TIMER Select the length of time you want with the unit on The unit automatically stops once the selected time is reached CANCELLATION If the power OFF Button is not pushed within 8 seconds of adjusting sensor sensitivity the setting will be saved automatically The sens...

Page 10: ...k for about 10 minutes 2 Rinse off the kitchen detergent with clean water 3 Completely dry the filter in a well ventilated area Wipe with a dry soft cloth For stubborn stains or dirt use a soft cloth dampened with warm water Do not use volatile fluids Benzine paint thinner polishing powder etc may damage the surface Do not use detergents Detergent ingredients may damage the unit SENSOR 1 Remove th...

Page 11: ...PLACING THE FILTER Replacement Filter Please consult your dealer for purchase of replacement filter Use only filter designed for this product Disposal of Filter Please dispose of the replaced filter according to the local disposal laws and regulations See page E 5 for directions on how to install the filter when replacing Replacement timing About 2 years after operating Be sure to remove the power...

Page 12: ...fficult for the sensor to detect cigarette smoke Is the dust sensor opening blocked or clogged In this case clean the opening Ref E 8 The DUST SIGN is turned off Check to see if the Lights OFF Mode selected Press for 3 seconds to light On Ref E 7 Check to see if the SLEEP mode is selected The DUST PLASMACLUSTER SIGN are turned off automatically after the SLEEP mode is selected The DUST SIGN lights...

Page 13: ...the unit at maximum fan speed It indicates the space where a certain amount of dust particles can be removed in 30 minutes JEM1467 3 Size of a room in which approximately 7000 ions can be measured per cubic centimeter in the center of the room at a height of approximately 1 2 meters from the floor when the product is placed next to a wall and run at the MED operation position Standby Power In orde...

Reviews: