[5] Mode switch test
1
Key operation
105
→
TL
2
Details of test
"x" must be read in proper sequence.
3
Check item
A) Check of the display in the test and the content of end print.
4
Test end
Normal end
105
Error
E - - - 105
[6] Printer sensor test
1
Key operation
106
→
TL
2
Details of test
Check the state of the paper near end sensor and the validation
sensor.
3
Check item
x, x:
Near end, receipt side, journal side
y, y:
Validation, receipt side, journal side
C:
Paper present
O:
Paper empty
"C" is displayed also when there are no sensors.
4
Test end
Press any key to terminate the test. The end print is as follows:
106
[7] Calendar oscillator test
1
Key operation
108
→
TL
Functional description
This program is used to test the calendar oscillator function.
2
Check the following items:
i)
Testing blinking "–". (500ms ON and OFF)
3
Test termination
Any key depression terminates the test with the termination print.
108
Test termination print
[8] SSP test
1
Key operation
109
→
TL
2
Functional description
If an SSP is programmed, its contents are automatically checked
and the result is printed.
3
Check the following items:
Check printing of the termination message.
4
Test termination
The test terminates automatically after printing the termination
print.
109
E
–
–
–
–
–
109
F
–
–
–
–
–
109
Normal end print
Error print SSP table full print (NOTE)
Note: In this SSP check, set the data for check in the empty area of
SSP entry REG and erase the data for check after completion
of check. Therefore, SSP setting before check is not cleared.
If, therefore, there is no SSP entry REG remained for SSP
check, F-print (SSP entry register full print) is performed to
terminate the program without check.
[9] Drawer open sensor test
1
Key operation
110~111
→
TL
2
Functional description
The drawer indicated by the job number is opened to check the
proper action.
Drawer opened: O indicated
Drawer closed:
C indicated
110: Drawer-1: Standard drawer
111: Drawer-2: Remote drawer
3
Check the following items:
a) Check opening of the specified drawer.
b) Check the display indication when the drawer is open and
closed.
4
Any key depression terminates the test with the termination print.
11X
Test termination print
X: 0~1
X
M O D E
S W
S R V
MODE:
x:
SRV_PGM1/2_TEXT_ _OP X/Z_REG_X1/Z1_X2/Z2___SRV
0
1
2
(E)
3
4
5
7
0
DOT DISPLAY:
7-SEGMENT DISPLAY:
x x
y y
S E N S O R
S R V
DOT DISPLAY:
7-SEGMENT DISPLAY:
* *
T I M E R
S R V
* *
* *
"
* *
"
DOT DISPLAY:
7-SEGMENT DISPLAY:
shows the current time.
1 2 3 4 5 6 7 8 9 0
S S P
T E S T
S R V
DOT DISPLAY:
7-SEGMENT DISPLAY:
x
D R A W E R Y
S R V
DOT DISPLAY:
7-SEGMENT DISPLAY:
X: O= Drawer opened
C= Drawer closed
Y: 1 or 2