62
Setting the time range for hourly reports
You can set the time range for an hourly report.
*A: Time range
To set the time range to 30 minutes (in the 24-hour system), enter 0.
To set the time range to 60 minutes (in the 24-hour system), enter 1.
BC: Starting time (hour = 00 to 23)
To perform this setting, an hourly Z report (# 160) must be done.
RS-232C channel assignment
Your machine is equipped with an RS-232C interface. If you use the on-line communication function, the
channel number of the RS-232C interface must be programmed by using the following procedure.
To realize the on-line communication, consult your dealer.
*P: 1
**
Item:
Selection:
Entry:
A
For the ON-LINE communication
Disable
0
Enable (enter the channel number)
8
B to D
Always enter 0.
0
*P: 2 and 3 (ABCD: Not used. Always enter 0.)
A through D
P
2690
. ≈
1
≈ :
;
Key operation
Example
2690
.
≈
≈
:
;
**ABCD
When A through D are all zeroes
1 to 3
*P
Procedure
2690
PGM 2
Note
2619
. ≈
107
;
Key operation
Example
2619
.
;
A B C
*
When A through C are all zeros
≈
Procedure
2619