– 55 –
CD-RW5000
Troubleshooting for CD-R unit
Check the items 1, 2 and 3. If the playback/recording operation is not possible, the CD-R unit is defective.
When no sound is heard during playback, check the item 4. If there are no output signals, CD-R unit is defective.
Stopped
27-JUL-00 09 58
50
µ
s/d
CH1=5V
DC P*10
CH2=5V
DC P*10
CH3=5V
DC P*10
1
2
3
1. Check of supply voltage
-8V Pin 1 of CNP808
+12V Pin 2 of CNP808
+5V Pins 6 and 7 of CNP808
2. Check of control signal from the system microcomputer
1. DATA Pin 7 of CNP912
2. CLOCK Pin 5 of CNP912
3. RESET Pin 3 of CNP912
3. Check of recording signal
CD or AUX OPT (Digital)
EBU INPUT Pin 1 of CNP911
OTHER FUNCTION (Analog)
A-IN L-ch, R-ch Pin 3 and 5 of CNP914
4. Check of playback signal
A-OUT L-ch, R-ch Pins 1 and 2 of CNP914
Troubleshooting during phono input of stereo turntable
Since this unit is not provided with an earth terminal, the hum noise may be increased during playback when it is connected to a
record player having an earth lead separated from a RCA lead.
In such a case, replace the screw shown in the following figure with XJBSD30P10000 and connect the earth lead of the player.
(Replace the black screw with a general un painted screw.)
Figure 55-1
Figure 55-2
VCR
To the line output
Red
White
RCA lead
RCA lead
Stereo turntable
MD deck,DSS tuners or DAT decks
To the line
output
socket
MD recorder
To the optical line input socket
Connection cable for
digital recording
Replace this screw and
connect the earth lead.