10
Perform the Drain Water function at least once a day
after cooking with steam. It takes up to 7 minutes.
The Drain Water Function helps prevent scale build up
and removes left over water.
P R O C E D U R E
1
Press
START/AUTO MIN-
UTE
. In F1 will fl ash on and off
in the display during the Drain
Water function.
2
Remove the water tank. Ensure
that no food is in the oven. Press
INFO/KITCHEN TIMER
once
to select In F1.
When the drain function has ended and the
oven is cool, wipe the oven cavity. Wait a few
minutes, then empty the drip tray.
3
NOTES:
1. The water tank must be removed before starting this
procedure.
2. If Drain Water Function is set, Energy Save Mode
will be cancelled temporary.
White or gray grains, also called scale, may form
in the water circuit inside the oven during steam
generation, which could cause the oven to malfunction.
When "DESCALE (fl ashing)" is shown in the display,
be sure to carry out Descale function immediately. It
takes about 1 hour (for descaling using citric acid is
for about 30 min. The rinse time is approx. 30 min.).
P R O C E D U R E
1
3
Do not place any food in the
oven. Close the door fi rmly. Press
START/AUTO MINUTE
to begin
descaling (for about 30 min.).
4
When the oven has stopped and is cool, remove
water tank, empty, rinse and refi ll with room
temperature drinking water to the MAX mark.
Replace the water tank. Empty the drip tray and
replace it.
Remove the glass tray, empty, rinse
and dry. Follow step 3 to replace
the glass tray. Close the door fi rmly.
Press
START/AUTO MINUTE
.
Rinsing will start (for about 30 min.).
5
When rinsing has ended and the oven is cool,
remove water tank and empty. Remove the glass
tray and empty. Wipe oven cavity to dry. Wait
a few minutes and then empty the drip tray.
6
Place the glass tray in lower position (position 2).
Ensure it is touching the back wall of the oven.
NOTE:
If Descale Function is set, Energy Save Mode will be
cancelled temporary.
IMPORTANT INSTRUCTIONS
Descale Function
Drain Water Function
x 1
x 1
Press
INFO/KITCHEN
TIMER
twice to select In F2.
x 2
2
x 1
x 1
Pure citric acid, available at some chemists, or
bottled 100% lemon juice with no pulp are used
for descaling. Choose one and prepare the
descaling solution.
To use pure citric acid, dissolve 1 tablespoon of
pure citric acid crystals in 500ml of water in a
non-porous container. Stir well and pour into the
water tank to the MAX mark.
To use 100% bottled lemon juice, check that
there is absolutely no pulp in it. If there is
pulp or you are not sure, strain through a fi ne
strainer. Measure 70ml of the strained lemon
juice and add it to 500ml of water. Stir well and
pour into the water tank to the MAX mark.
Place the water tank in the oven correctly and
push fi rmly into place.