3-43
CHAPTER 3 SADDLE STITCH UNIT BASIC OPERATION
VII.POWER SUPPLY
1.
Outline
When the host machine power switch is turned ON, 24V and 5V power lines are supplied by
the finisher controller PCB.
The 24V power is used to drive solenoids. The 24V power from the finisher controller PCB to
solenoids does not pass through any protective mechanisms (microswitches, or the like).
The 24V power to motors, on the other hand, will not be supplied if any of the three door
switches is open.
The 5V power is used to drive sensors and ICs.
J19-1
J3-2
J1-1
J2-5
Finisher
controller
PCB
Circuit
breaker
Saddle stitch
controller PCB
Inlet door
switch
Front door
switch
Delivery
door switch
Motor systems
Solenoids
Sensors
Logic
Power source
24V
5V
24V
Figure 3-701
2.
Protective Mechanisms
The 24 VDC power supply used for motors and solenoids is equipped with a circuit breaker
(CB1). The 24V power supply used to drive the feed motor (M1S), alignment motor (M5S), and the
paper positioning plate motor (M4S) is equipped with a fuse designed to blow when an overcurrent
flows.
F15/F16
Summary of Contents for AR-F15
Page 8: ......
Page 36: ......
Page 77: ...2 41 CHAPTER 2 FINISHER UNIT BASIC OPERATION Height sensor PS1 Paper Figure 2 240 ...
Page 94: ......
Page 110: ...3 16 CHAPTER 3 SADDLE STITCH UNIT BASIC OPERATION Figure 3 302 ...
Page 124: ...3 30 CHAPTER 3 SADDLE STITCH UNIT BASIC OPERATION Cam Mount Figure 3 404 ...
Page 138: ...3 44 CHAPTER 3 SADDLE STITCH UNIT BASIC OPERATION ...
Page 140: ......
Page 156: ......
Page 202: ......
Page 214: ......
Page 223: ...7 9 CHAPTER 7 TROUBLESHOOTING II ARRANGEMENT OF ELECTRICAL PARTS A Finisher Unit ...
Page 260: ...7 46 CHAPTER 7 TROUBLESHOOTING ...
Page 262: ......
Page 273: ...A 11 APPENDIX Q500 FF3 4071 SADDLE RELAY BUNDLE WIRE ...
Page 276: ...Memo ...
Page 277: ...Memo ...