AR-203E/5420/M200/M201 SIMULATION, TROUBLE CODES 10 - 15
26
40
Polygon motor OFF time
setup (Time required for
turning OFF after completion
of printing)
[Function]
When this simulation is executed, the current setting is displayed. Enter the code number corre-
sponding to the desired setting and press [OK]/[ENTER]/[START] key to save the setting.
[Operation]
The operation is similar to simulation 26-02.
42
Transfer ON timing control
setup
[Function]
[Operation] (AR-M200/M201)
Main
code
Sub
code
Contents
Details of function/operation
Code number
Setting
Display item
Remark
AR-M200/M201
AR-203E/5420
0
0sec
0 SEC.
0
1
30sec
30 SEC.
30
Default
2
60sec
60 SEC.
60
3
90sec
90 SEC.
90
AR-203E/5420
When this simulation is executed, the currently set code number is displayed.
Enter the code number and press the [START] key, and the setting will be changed. (For any
number different from the following ones, the default time is automatically set.)
<Paper lead edge adjustment table>
* The default value, "11," of the transfer ON timing indicates "236msec passed from PS
release."
* When set to "0," it is same as setting to the default, "11."
* The transfer ON timing can be adjusted to 236msec ± 2ms.
AR-M200/M201
For the AR-M200/M201, the adjustment can be made individually for each of the following
modes.
<Paper lead edge adjustment table> is the same as that of the AR-203E/5420 above.
<Front/back surface of paper rear edge adjustment table>
* The default "50" of the transfer OFF timing indicates "210msec passed from PPD1OFF."
* The transfer OFF timing can be adjusted to 210msec ± 2ms.
Code number
Setting
Code number
Setting
0
Default (236 msec)
11
Default (236 msec)
1
–20 msec
12
+2 msec
2
–18 msec
13
+4 msec
3
–16 msec
14
+6 msec
4
–14 msec
15
+8 msec
5
–12 msec
16
+10 msec
6
–10 msec
17
+12 msec
7
–8 msec
18
+14 msec
8
–6 msec
19
+16 msec
9
–4 msec
20
+18 msec
10
–2 msec
21
+20 msec
Mode
Display item
Default
Setting range
Front surface paper lead edge
F-REAR
11
0 - 21
Front surface paper rear edge
F-END
50
1 - 99
Back surface paper lead edge
B-REAR
11
0 - 21
Back surface paper rear edge
B-END
50
1 - 99
Code
Setting
Remark
1
–98 msec
. . .
. . .
49
–2 msec
50
0 msec
Default
51
+2 msec
. . .
. . .
99
+98 msec
1) Initial display
<Front surface lead edge setting>
2) [
] [
] key: Mode selection
3) [Numeric] key: Value entry
4) [OK]/[ENTER]/[START] key:
Settles the entered value. The display is
shifted to the sub code input standby
menu.
26-42 TC ON TIMING
F-REAR 11( 0-21 )
26-42 TC ON TIMING
F-END 50( 1-99 )
26-42 TC ON TIMING
F-END 51( 1-99 )
Summary of Contents for AR-203E X