AR-203E/5420/M200/M201 SIMULATION, TROUBLE CODES 10 - 2
24
15
Scanner mode counter clear
(AR-203E/M200/M201)
25
01
Main motor operation check
(Cooling fan motor rotation check)
10
Polygon motor ON
26
02
SPF/RSPF setup
03
Second cassette setup
04
Machine duplex setup
06
Destination setup
07
Machine conditions check
20
Rear edge void setup
30
CE mark support control ON/OFF
37
Cancel of stop at developer life over
39
Memory capacity check
40
Polygon motor OFF time setup (Time required for
turning OFF after completion of printing)
42
Transfer ON timing control setup
43
Side void setup
54
γ
life correction setting
62
Energy-save mode copy lamp setup
30
01
Paper sensor status display
41
06
OC cover float detection level adjustment (Only the
AR-203E/M200/M201 with the SPF/RSPF
installed)
07
OC cover float detection margin setting (Only the
AR-203E/M200/M201 with the SPF/RSPF
installed)
43
01
Fusing temperature setting (Normal copy)
04
Fusing temperature setting in multi copy
05
Fusing temperature setup in duplex copy
(AR-M201 only)
14
Fusing start temperature setting
46
01
Copy density adjustment (300dpi)
02
Copy density adjustment (600dpi)
12
Density adjustment in the FAX mode
(Collective adjustment)
(Executable only when the FAX is installed.)
13
FAX mode density adjustment (Normal text)
(Executable only when the FAX is installed.)
14
FAX mode density adjustment (Fine text)
(Executable only when the FAX is installed.)
15
FAX mode density adjustment (Super fine)
(Executable only when the FAX is installed.)
18
Image contrast adjustment (300dpi)
19
Exposure mode setup
20
SPF/RSPF exposure correction (Only the
AR-203E/M200/M201 with the SPF/RSPF installed)
29
Image contrast adjustment (600dpi)
30
AE limit adjustment
31
Image sharpness adjustment
32
Copier color reproduction setup
39
FAX mode sharpness adjustment
(Executable only when the FAX is installed.)
48
01
Front/rear (main scanning) direction and scan (sub
scanning) direction magnification ratio adjustment
05
SPF/RSPF mode sub scan direction magnification
ratio in copying (Only the AR-203E/M200/M201
with the SPF/RSPF installed)
49
01
Flash ROM program writing mode
50
01
Lead edge image position
06
Copy lead edge position adjustment (SPF/RSPF)
(Only the AR-203E/M200/M201 with the
SPF/RSPF installed)
10
Center offset adjustment
Sim
No.
Sub
code
Operation
50
12
Document off-center adjustment
18
Memory reverse position adjustment in duplex
copy (Only the AR-M201, or the AR-M200 with the
RSPF installed)
19
Duplex copy rear edge void adjustment
(AR-M201 only)
51
02
Resist quantity adjustment
53
08
SPF/RSPF scan position automatic adjustment
(Only the AR-203E/M200/M201 with the
SPF/RSPF installed)
61
03
Polygon motor check (HSYNC output check)
63
01
Shading check
02
Black level automatic correction
12
Light quantity stabilization wait time setting
13
Light quantity stabilization band setting
64
01
Self print (1by2 mode)
66
01
FAX soft SW setting
(Executable only when the FAX is installed.)
02
FAX soft SW initializing
(excluding the adjustment values)
(Executable only when the FAX is installed.)
03
FAX PWB memory check
(Executable only when the FAX is installed.)
04
Signal send mode (Max. value)
(Executable only when the FAX is installed.)
05
Signal send mode (Soft SW set value)
(Executable only when the FAX is installed.)
07
Image memory content print
(Executable only when the FAX is installed.)
10
Image memory content clear
(Executable only when the FAX is installed.)
11
300bps signal send (Max. value)
(Executable only when the FAX is installed.)
12
300bps signal send (Soft SW set value)
(Executable only when the FAX is installed.)
13
Dial test
(Executable only when the FAX is installed.)
17
DTMF signal send (Max. value)
(Executable only when the FAX is installed.)
18
DTMF signal send (Soft SW set value)
(Executable only when the FAX is installed.)
21
FAX information print
(Executable only when the FAX is installed.)
24
FAST SRAM clear
(Executable only when the FAX is installed.)
30
TEL/LIU status change check
(Executable only when the FAX is installed.)
33
Signal detection check
(Executable only when the FAX is installed.)
34
Communication time measurement
(Executable only when the FAX is installed.)
37
Speaker sound volume setting
(Executable only when the FAX is installed.)
38
Time setting/check
(Executable only when the FAX is installed.)
67
50
USB receive speed adjustment (USB1.1)
(AR-203E only)
Sim
No.
Sub
code
Operation
Summary of Contents for AR-203E X
Page 172: ...Memo ...