5. The solenoid turns off to close the gate and return to the in-
itial state.
C. Conditions of occurrence of paper misfeed
(1) When the power is turned on:
PPD or POD is ON when the power is turned on.
(2) Copy operation
a. PPD1 jam 1) PPD1 does not turn off within 4 sec
after turning on the resist roller.
b. PPD2 jam 1) PPD2 is off immediately after turning on
the resist roller.
2) PPD2 does not turn off within 1.2 sec
after turning off the resist roller.
c. POD jam
1) POD does not turn on within 2.9 sec
after turning on the resist roller.
2) POD does not turn off within 1.5 sec
∼
2.7 sec after turning off PPD2.
Process unit new drum detection
mechanism
1. When the power is turned on, the detection gear 38T is
rotated in the arrow direction by the detection gear 20T to
push the microswitch (process detection switch) installed to
the machine sensor cover, making a judgement as a new
drum.
2. When the detection gear 38Y turns one rotation, there is no
gear any more and it stops.
The latch section of the 38T gear is latched and fixed with
the projection of the process cover.
OF
MPFS
F
A
C
Gear 20T
Process detection switch
Gear 38T
Gear notch
Gear pawl
Projection
Gear notch
Gear pawl
Projection
AL-1000/1010
7-8
Summary of Contents for AR-121E
Page 126: ... 13 CIRCUIT DIAGRAM AC INTERLOCK AL 1000 1010 13 1 ...
Page 127: ...MCU1 AL 1000 1010 13 2 ...
Page 128: ...MCU2 AL 1000 1010 13 3 ...
Page 129: ...MCU3 AL 1000 1010 13 4 ...
Page 130: ...MCU4 AL 1000 1010 13 5 ...
Page 131: ...MCU5 AL 1000 1010 13 6 ...
Page 132: ...MCU6 AL 1000 1010 13 7 ...
Page 133: ...OPU AL 1000 1010 13 8 ...
Page 134: ...POWER SUPPLY 100V 110V AL 1000 1010 13 9 ...
Page 135: ...POWER SUPPLY 120V 127V AL 1000 1010 13 10 ...
Page 136: ...POWER SUPPLY 200V Series AL 1000 1010 13 11 ...