7) Clean the cleaning section and the waste toner pipe to remove
waste toner completely with a vacuum cleaner.
8) Remove the felt and duplex tape completely.
Note: Be careful not to scratch or bend the sub blade.
9) Attach the cleaning blade.
Securely insert the plate section of the cleaning blade into the
dove and fix it with a screw.
Do not touch the cleaning blade rubber with your hand.
When attaching the cleaning blade, press the cleaning blade in the
arrow direction and attach.
10) Attach the felt.
Attach the mocket with slightly pressing section A of the cleaning blade.
Do not touch the tip of the cleaning blade.
Do not put the mocket under the cleaning blade.
Do not put the mocket on the sub blade.
Do not press the sub blade with the mocket.
11) Attach the main charger.
Securely set the MC holder on the projection of the process frame.
Securely insert two projections of the MC holder into the groove
in the process frame.
When attaching the MC holder ass’y, be careful not to make con-
tact with the cleaning blade.
12) Attach the drum fixing plate and the photoconductor drum.
Apply grease to the inside of the photoconductor drum. (Dia. 2)
Attach the drum from (b). (Prevention against the sub blade edge
breakage)
Attach the drum so that its position with the sub blade is as shown.
13) Attach the detection gear.
Note:
•
The detection gear is not installed to the drum cartridge packed
with the main body. Add a new one.
14) Attach the drum cover.
Note: After attaching the drum cover, do not make a copy.
When attaching the drum cover, engage the detection gear
20T rib with the 30T gear rib, and attach the drum cover to
the process frame.
15) Mark the number of times of recycling on the side of the cover with
white paint.
Max. times of recycling: 5 times
Note: Another method of cleaning the drum counter is avail-
able with SIM 24-07.
AR-150E
3 – 7
Summary of Contents for AR-121E
Page 126: ... 13 CIRCUIT DIAGRAM AC INTERLOCK AL 1000 1010 13 1 ...
Page 127: ...MCU1 AL 1000 1010 13 2 ...
Page 128: ...MCU2 AL 1000 1010 13 3 ...
Page 129: ...MCU3 AL 1000 1010 13 4 ...
Page 130: ...MCU4 AL 1000 1010 13 5 ...
Page 131: ...MCU5 AL 1000 1010 13 6 ...
Page 132: ...MCU6 AL 1000 1010 13 7 ...
Page 133: ...OPU AL 1000 1010 13 8 ...
Page 134: ...POWER SUPPLY 100V 110V AL 1000 1010 13 9 ...
Page 135: ...POWER SUPPLY 120V 127V AL 1000 1010 13 10 ...
Page 136: ...POWER SUPPLY 200V Series AL 1000 1010 13 11 ...