LC-60/70LE360X
6 – 2
LCD TV ADJUSTMENT ITEM
1. VCOM ADJUSTMENT
i. Enter service mode key and go to VCOM/TEST PATTERN Page
ii. Press “Enter” key (at VCOM)
iii. Adjust the flicker effect by pressing “VOL +/-“ of RC key
iv. Press “Enter” key after get the best value
2. MAIN SOFTWARE PACKAGE
e
g
a
k
c
a
P
e
r
a
w
t
f
o
S
l
e
d
o
M
LC-60LE360X
LC-70LE360X
Wisteria2_Asia_Pack08_vXXX.bin
Main Software Filename
: XXX is Software version
Please manually change the panel inch setting (60” or 70”) according to the model.
If any changes of software, will be informed by MARUHEN.
3. T-CON ROM DATA INPUT (T-CON PWB : QPWBXG476WJ**)
E
R
U
D
E
C
O
R
P
N
O
I
T
I
D
N
O
C
M
E
T
I
1 T-CON Data
Input
(T-CON PWB)
Checker
adjustment
Full version
confirmation
1. At checker, connect software jig at
SC6151 (TL6151~6157).
2. Input
voltage
at
P4804 (TL4839~TL4892)
and ROM start to
input data.
3. Power OFF after finish data input.
[ Caution item ]
If some error happened, ROM data is not written in at all.
Note: Please refer to below for combination of T-Con software
LCD PANEL
T-CON UNIT
T-CON SOFTWARE
1
R1JE601D3HA10W
(LC-60LE360X)
DUNTKG476FM01
Turnip_f03_140514_fmt600501.ROM
2
R1JE695D3HC50W
(LC-70LE650M/X)
DUNTKG476FM02
Turnip_f03_140514_fmt700501.ROM
4. C.I + KEY PROGRAMMING
C.I PLUS key disk name & no.
: CI_PLUS_MST_XXXX.dat
(Key is from Sharp IT department)
Please be extra careful in data management so as NOT to write multiple data. Also, when data writing
location parts is broken, please change PWB board (since the concerned IC is non-exchangeable part).
Summary of Contents for Aquos LC-60LE360X
Page 12: ...LC 60 70LE360X 5 2 LC 70LE360X 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 7 ...
Page 34: ...LC 60 70LE360X 8 1 CHAPTER 8 SYSTEM BLOCK DIA GRAM 1 SYSTEM BLOCK DIAGRAM LC 60LE360X ...
Page 35: ...LC 60 70LE360X 8 2 2 SYSTEM BLOCK DIAGRAM LC 70LE360X ...
Page 61: ...LC 60 70LE360X 9 26 ...
Page 72: ...LC 60 70LE360X 11 ...