40
LC-26D7U
LC-32D7U
LC-37D7U
(2) List of adjustment commands
Use the following RS-232C commands for adjustment.
Item
Commands
Description
1
Two-point
MSET0000
adjustment
start
2
Adjustment value
MSET0004
initialization
3
Adjustment value
MSET0003
saving
4
Low-side
SDML0057
adjustment
point setting
5
Low-side R
MGLRXXXX
adjustment
6
Low-side G
MGLGXXXX
adjustment
7
Low-side B
MGLBXXXX
adjustment
8
High-side
SDMH0204
adjustment
point setting
9
High-side R
MGHRXXXX
adjustment
10
High-side G
MGHGXXXX
adjustment
11
High-side B
MGHBXXXX
adjustment
12
Adjustment
SMGAXXXX
pattern display
Starts white balance adjustment (two-point adjustment).
All commands received after this command operate as a two-point adjustment
command.
Initializes adjustment values.
Adjustment value buffer in the set is initialized.
Saves adjustment values.
Parameters set by commands are saved to EEPROM.
Sets low-side adjustment point.
Parameter: 0 - 255
After executing this command, a gradation pattern appears according to the
specified parameter. Adjustment values are initialized with the value specified
by the parameter (RGB are the same value).
The initialized commands are MGLR, MGLG, and MGLB. The value set as a
default is four times larger than that of the parameter.
(Example: For SDML0048, default of MGLR, MGLG, and MGLB are 192.)
Adjusts R gamma of the low-side adjustment point.
Parameter: 0 - 1023
R gamma of the adjustment pattern is reset with the parameter value.
Adjustment value buffer in the set is overwritten with the parameter value.
Adjusts G gamma of the low-side adjustment point.
Parameter: 0 - 1023
G gamma of the adjustment pattern is reset with the parameter value.
Adjustment value buffer in the set is overwritten with the parameter value.
Adjusts B gamma of the low-side adjustment point.
Parameter: 0 - 1023
G gamma of the adjustment pattern is reset with the parameter value.
Adjustment value buffer in the set is overwritten with the parameter value.
Sets high-side adjustment point.
Parameter: 0 - 255
After executing this command, a gradation pattern appears according to the
specified parameter. Adjustment values are initialized with the value specified
by the parameter (RGB are the same value).
The initialized commands are MGHR, MGHG, and MGHB. The value set as
a default is four times larger than that of the parameter.
(Example: For SDMH0200, default of MGHR, MGHG, and MGHB are 800.)
Adjusts R gamma of the high-side adjustment point.
Parameter: 0 - 1023
R gamma of the adjustment pattern is reset with the parameter value.
Adjustment value buffer in the set is overwritten with the parameter value.
Adjusts G gamma of the high-side adjustment point.
Parameter: 0 - 1023
G gamma of the adjustment pattern is reset with the parameter value.
Adjustment value buffer in the set is overwritten with the parameter value.
Adjusts B gamma of the high-side adjustment point.
Parameter: 0 - 1023
G gamma of the adjustment pattern is reset with the parameter value.
Adjustment value buffer in the set is overwritten with the parameter value.
Displays an adjustment pattern.
Parameter: 0 - 1023
The gradation pattern (raster) specified by the parameter appears (same
values for RGB).
* This command does not affect the adjustment values.
Summary of Contents for Aquos LC 26D7U
Page 16: ...16 LC 26D7U LC 32D7U LC 37D7U Dimensions Unit inch mm Unit inch mm LC 26D7U LC 32D7U ...
Page 17: ...17 LC 26D7U LC 32D7U LC 37D7U Dimensions Unit inch mm LC 37D7U ...
Page 46: ...46 LC 26D7U LC 32D7U LC 37D7U 6 List of adjustment process modes Display Examples ...
Page 47: ...47 LC 26D7U LC 32D7U LC 37D7U 5 ...
Page 67: ...67 LC 26D7U LC 32D7U LC 37D7U M E M O ...
Page 165: ...8 7 1 10 9 6 5 4 3 2 1 A B C D E F G H 11 13 12 15 14 17 16 19 18 21 20 ËAV Unit 3 7 D11 D12 ...
Page 168: ...8 7 1 10 9 6 5 4 3 2 1 A B C D E F G H 11 13 12 15 14 17 16 19 18 21 20 ËAV Unit 5 7 D17 D18 ...
Page 173: ...6 5 4 3 2 1 A B C D E F G H 6 5 4 3 2 1 A B C D E F G H ËKEY Unit D27 D28 ËR C LED Unit ...
Page 214: ...6 5 4 3 2 1 A B C D E F G H ËSP L Unit D109 ËSP R Unit ...