3-14
AY-ZP35PR
[8] TROUBLESHOOTING GUIDE
1. Self-Diagnosis Function
1. Indoor unit
To display the self-diagnosis, hold down the AUX button for over 5 seconds on the indoor unit when the indoor unit is not operating.
The operation lamp (green), timer lamp (orange) and Plasmcluster lamp (blue) flash to indicate the information of mulfunction.
If the power cord is unplugged or the circuit breaker is turned off, the self-diagnosis memory is lost.
Display of self-diagnosis result
The operation lamp (green) and the Plasmacluster lamp (blue) flash in synchronization with the timer lamp (orange).
2. Outdoor unit
The self-diagnosis is indicated the error information by flashing LED1 on the outdoor unit.
The self-diagnosis of outdoor unit is displayed for about 3-10 minutes. Then, the LED1 returns to normal display.
Timer lamp (1 cycle)
LED1
2-time
ON
OFF
1-second
OFF
1-second
OFF
1-second
OFF
1-second
ON
1-second
ON
1-second
ON
1-second
ON
3-time
Normal
ON
OFF
1-second
OFF
1-second
OFF
1-second
OFF
0.5-second
ON
1-second
ON
0.5-second
ON
1-second
ON
2-time
ON
OFF
1-second
OFF
1-second
OFF
1-second
OFF
0.5-second
ON
1-second
ON
0.5-second
ON
0.5-second
ON
1-second
ON
3-time
PLASMACLUSTER Lamp (blue)
OPERATION Lamp (green)
TIMER Lamp (orange)
AUX