4 – 1
EHP6.0AA/I
5GTXKEG/CPWCN
CHAPTER 4.
REFRIGERATION CYCLE
[1] SCHEMATIC DIAGRAM
[2] STANDARD CONDITION
*
REFRIGERANT PIPE LENGTH 5m
[3] TEMPERATURE AT EACH PART AND PRESSURE IN 3-WAY VALVE
*
On test run mode
[4] PERFORMANCE CURVES
NOTE
1) Indoor fan speed: Hi
Cooling
Heating
27
20
47
35
40
87
2) Vertical adjustment louver "front”, Horizontal adjustment louver "level"
3) Indoor air temp. : Cooling 27
°
C, Heating 20
°
C
4) Power source : 230V, 50Hz
5) Compressor speed : Rated frequency
Dry-bulb Temp. (
Indoor side
Outdoor side
°
C)
Relative Humidity (%)
Dry-bulb Temp. (
°
C)
Relative Humidity (%)
7
–
Model
AY-ZP35PR
NO. Condition
Cooling
Heating
Temp. on
(
°
C)
60
58
Temp. on
(
°
C)
37
3
Temp. on
(
°
C)
17
25
Temp. on
(
°
C)
16
6
3-way valve pressure (MPaG)
1.0
2.2
AY-ZP40PR
Cooling
Heating
61
57
37 3
17
25
16 7
1.0 2.2
AY-ZP35PR
s
1
4
C
2
Accumulator
3
Strainer
Expansion
valve
Heating
Cooling
Outdoor unit
Condenser
Evaporator
Indoor unit
Reverse valve
Comp-
ressor
Flare coupling
Flare coupling
3-way
valve
2-way
valve
Silencer
Coil
Antifreeze
pipe
Silencer