GB-1
INSTALLATION DIAGRAM
NOTES ON LOCATIONS
Provide as much installation space as possible for efficient
air-conditioning.
5.9 inch (150 mm) or more
11.8 inch (300 mm)
or more
Indoor unit
1. Keep the air outlet clear of any obstacle so that outgoing air flows
smoothly in the entire room.
2. Make a drain hose hole that will allow easy condensate water drain-
age.
3. Provide sufficient space on both sides and above the unit.
4. The unit must be installed with enough space allowance so that the
air filters can be removed and replaced easily.
5. Keep TV set, radio and other similar appliances at least 3.3 feet (1
m) or more away from the unit and the remote control.
6. Keep the air inlet clear of obstacles that could block incoming air,
and clean the air filter regularly.
7. The remote control may not function properly in a room equipped with
an electronic simultaneous-start or rapid-start fluorescent lighting.
8. Select a location that does not cause loud operation noise and ex-
treme vibrations.
Outdoor unit
1. Place the outdoor unit on a stable base.
2. Provided sufficient space around the unit. It should also be well venti-
lated.
3. The unit should not be exposed to strong wind nor splashed with
rain water.
4. Water should be drained from the unit. Lay a drain hose if required.
In cold regions, installation of the drain pipe is not advisable as
freezing could result.
5. Keep TV sets, Radios and other related electronic appliances at
least 3.3 feet (1 m) away from the unit.
6. Avoid locations exposed to machine oil vapor, salty air (facing the
seashore, for example), hot spring vapor sulfur gas, etc. Such loca-
tion can cause breakdown.
7. Avoid locations exposed to muddy water (along a road, for example)
or where the unit can be tampered with.
8. Select a location where the outgoing air or operating noise cannot
annoy others.
9. Keep the air outlet opening free of any obstacle. This could affect the
performance of the unit and create loud noises.
10.For colder climate areas, install the unit in a location not affected
by snow or ice falls (example: roof houses). Unit should be installed
minimum 10 inches (25 cm) from ground level or follow your coun-
try’s average snowfall accumulation.
Carefully read and follow these instructions for smooth and trouble-free installation.
Coating tape
(Commercially
available)
ENGLISH
SAFETY PRECAUTIONS
• Tighten the flare nut with a torque wrench according to the specified
method.
If the flare nut is tightened too hard, the flare nut may be broken after a
long time and cause refrigerant gas leakage.
• When installing the unit, do not to add an air substance other than
the specified refrigerant(R410A) in the refrigerant cycle.
Otherwise, it will cause burst and injury as a result of abnormal high pres-
sure in the refrigerant cycle.
• Be sure to connect the refrigerant pipe before running the compres-
sor.
Otherwise, it may burst and cause injury as a result of abnormal high pres-
sure in the refrigerant cycle.
• Ground the unit.
Incomplete ground may cause electrical shock.
• Install a Ground Fault Interrupt (GFI) circuit breaker depending on
the installation location of the unit (such as highly humid areas).
If GFI breaker is not installed, it may cause electric shock.
• Arrange the drain hose to ensure smooth drainage.
Insufficient drainage may cause wetting of the room, furniture etc.
• This room air conditioner uses refrigerant R410A.
Use the pipe, flare nut and tools exclusively for R410A.
• Installation must be made in accordance with the installation
manual by qualified service personnel.
Incorrect work will cause electric shock, water leak, fire.
• Be sure to use the attached accessories parts and specified
parts for installation.
Use of other parts will cause electric shock, water leak, fire, the unit
falling.
• The appliance shall be installed and wired in accordance with
National Electrical Code and by qualified personnel only.
Wrong connection can cause overheating or fire.
• After installation has completed, check that there is no leakage
of refrigerant gas.
If the refrigerant gas contact with fire, it may generate toxic gas.
• Ventilate the room if refrigerant gas leaks during installation.
If the refrigerant gas contact with fire, it may generate toxic gas.
• Use the specified electrical cable.
Make sure the cable is secured in place and that the terminals are
free of any excess force from the cable. Otherwise overheating or
fire may result.
• Form the cable so that the control box cover, the cord holder
and cable holder are not loose.
Otherwise overheating, fire or electric shock may result.
5.9 inch (150 mm)
or more
5.9 inch (150 mm)
or more
19.7 inch (500 mm)
or more
78.7 inch (2000 mm)
or more
19.7 inch (500 mm) or more
11.8 inch (300 mm)
or more
ITEMS
Q’ty
ITEMS
Q’ty
ITEMS
Q’ty
ITEMS
Q’ty
ITEMS
Q’ty
1
MOUNTING PLATE
1
3
REMOTE CONTROL
1
5
FLARE NUT
(1/4”, 5/8”)
1
set
7
BASE PAN CAP
1
set
9
WIRED CONTROL KIT
(Included with the
outdoor unit)
1
set
2
LONG SCREW
(M4.2 x 25)
To fix the mounting plate.
7
4
DRY BATTERY
2
6
DRAIN HOSE
ADAPTER
(Included with the
outdoor unit)
1
8
INSULATION
1
10
OPERATION MANUAL
1
11
INSTALLATION MANUAL
1
ACCESSORIES
AYX36RU_IM_3_lang.indb 1
2014-09-12 07:59:32