36U-S610
9
SERVICE ADJUSTMENT
RF AGC Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "R01".
3. Set the data value to point where no noise or beat
appears.
4. Select another channel to confirm that no noise or
beat appears.
Note 1 : You will have to come out of the service
mode to select another channel.
Note 2 : Setting the data to "00" will produce a black
raster.
Screen Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "V03" and set the data value to "00" to
set the color level to minimum. (Record original data
code under adjustment "V03" before changing) You
may skip this step, if you selected a B/W picture or
monoscope pattern.
3. Select the service adjustment "V18" and adjust the
data value to "01", this turn off the luminance signal
(Y-mute).
4. Adjust the master screen control until the raster
darkens to the point where raster is barely seen.
5. Adjust the service adjustments "V06" red, "V07" green
and "V08" blue to obtain a good grey scale with normal
whites at low brightness level.
6. Select the service adjustment "V18" and reset data
to "00". Select the service adjustment "V03" and reset
data to obtain normal color level.
7. For component input, the data value of "V46" red,
"V47" green and "V48" blue is adjusted to follow the
data value of "V06", "V07" and "V08" respectively.
8. Reset the master screen control to obtain normal
brightness range.
White Balance Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "V03" and set to "00" (minimum
color)(Record original data code under adjustment
"V03" before changing). "V03" does not have to be
adjusted, if you selected a B/W picture or monoscope
pattern.
3. Alternately adjust the service adjustment data of
"V09" and "V10" until a good grey scale with normal
whites is obtained. (RF Input)
4. For component input, the data value of "V49" and
"V50" is adjusted to follow the data value of "V09"
and "V10" respectively.
5. Select the service adjustment "V03" and reset data
to obtain normal color level.
Picture Adjustment
1. Receive a good local channel.
2. Make sure the customer picture control is set to
maximum.
3. Enter the service mode and select the service
adjustment "V01".
4. Adjust the data value to achieve normal contrast
range.
5. For component input, enter the service mode and
select the service adjustment "V42".
6. Adjust "V42"data value to obtain normal contrast
range.
Tint Adjustment
1. Receive a good local channel.
2. Set customer tint control to center of it's range.
3. Enter the service mode and select the service
adjustment "V02".
4. Adjust "V02" data value to obtain normal flesh tones.
5. Input same data to "V41".
Sub-Color Adjustment
1. Receive a good local channel.
2. Make sure the customer color control is set to center
position .
3. Enter the service mode and select service adjustment
"V03".
4. Adjust "V03" data value to obtain normal color level.
Brightness Adjustment
1. Receive a good local channel.
2. Make sure the customer brightness control is set to
center position.
3. Enter the service mode and select the service
adjustment "V05".
4. Adjust "V05" data value to obtain normal brightness
level.
5. For component input, enter the service mode and
select the service adjustment "V45".
6. Adjust "V45"data value to obtain normal contrast
range.
Summary of Contents for 36US50
Page 12: ...36U S610 6 5 4 3 2 1 A B C D E F G H 12 CHASSIS LAYOUT ...
Page 13: ...36U S610 6 5 4 3 2 1 A B C D E F G H 13 BLOCK DIAGRAM ...
Page 15: ...36U S610 16 15 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM MAIN 1 Unit ...
Page 16: ...12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM MAIN 2 Unit 36U S610 18 17 ...
Page 17: ...6 5 4 3 2 1 A B C D E F G H 19 SCHEMATIC DIAGRAM CRT Unit ...
Page 18: ...36U S610 21 20 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM AV Unit ...
Page 19: ...36U S600 23 22 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM P IN P Unit ...
Page 20: ...36U S600 6 5 4 3 2 1 A B C D E F G H 24 SCHEMATIC DIAGRAM MTS MODULE Unit ...
Page 21: ...36U S610 6 5 4 3 2 1 A B C D E F G H 25 PWB A MAIN Unit Wiring Side ...
Page 22: ...36U S610 6 5 4 3 2 1 A B C D E F G H 26 PWB A MAIN Unit Chip Parts Side ...